⚫ Keep doors and windows closed for better energy saving.
⚫ Do not operate or store the unit in direct sunlight or rain.
⚫ It is normal for air outlet to feel warm to touch after continuous operation on hot days.
⚫ Empty the water tank before moving the appliance.
⚫ Make sure the Water tank is correctly fitted otherwise the unit will not operate properly.
⚫ The dehumidifier starts up in the mode selected when the unit was last used.
⚫ The dehumidifier starts dehumidifying if the room humidity is 3% higher than the selected humidity.
⚫ There is a protective 3-minutes time delay before operation or shutting down of the compressor.
Wait 3 minutes for the dehumidifier to resume operation.

5. OPERATION

5.1 CONTROL PANEL

Power
After switching on the power, all the indicators and the screen will be lit for 1 second and then
turn off. A buzzer will sound and the power indicator light will be on and the machine will be in standby
mode.
Press the power button again and the appliance will start, the machines default initial humidity setting is
50%RH, the mode is set to automatic and the fan operation to high.
Press this key again, the machine will stop running, and the fan will stop after approx. 30s.
Mode
Auto mode - Continuously drying mode - Sleep mode. Press once to switch the mode from one to
another, the corresponding indicator lights up.
● Auto mode:
when room humidity ≥ set humidity +3%, the fan starts working and compressor