  • Page 1 EH1932 INSTRUCTION MANUAL 12 Litre / Day Dehumidifier Please keep this manual for further reference! Thank you for selecting this Prem-i-air dehumidifier. Be sure to read this manual carefully before use.
  • Page 2: Before You Begin

    1. BEFORE YOU BEGIN Please read the operating instructions carefully before using your dehumidifier for the first time. 1.1 PRODUCT DESCRIPTION The dehumidifier is used to remove excessive moisture from the air. The resulting reduction in relative humidity protects buildings and their contents from the adverse effects of excess humidity. The environmentally friendly R290 is used as the refrigerant.
  • Page 3: For Your Safety

    personnel to attempt to find the cause. The propane gas used in the unit has no odor. The lack of smell does not indicate a lack of escaped gas. ⚫ If a leak is detected, immediately evacuate all persons from the area, ventilate the room and contact the fire brigade to advise them that a propane leak has occurred.
  • Page 4 ⚫ Do not leave the unit running unattended. Do not tilt or turn over the unit. ⚫ Do not unplug while the unit is operating, this may cause damage and unwanted wear. ⚫ Do not unplug by pulling on the power cord. ⚫...
  • Page 5 Please follow these warnings when to undertake the following when servicing a dehumidifier with R290. 2.2.1 Checks to the area Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
  • Page 6: Product Overview

    Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: –...
  • Page 7: Installation

    4. INSTALLATION 4.1 LOCATION 1. Place the unit on a firm, level surface in an area with at least 30cm of free space around it to allow for proper air circulation. 2. Never install the unit where it could be subject to: ⚫...
  • Page 8: Operation

    ⚫ Keep doors and windows closed for better energy saving. ⚫ Do not operate or store the unit in direct sunlight or rain. ⚫ It is normal for air outlet to feel warm to touch after continuous operation on hot days. ⚫...
  • Page 9 ● Auto mode: when room humidity ≥ set humidity +3%, the fan starts working and compressor starts working after 3 seconds. When room humidity ≤ set humidity -3%, the compressor stops working and the fan will shut down after a short 30s delay. Both fan speed and humidity can be adjusted under auto mode.
  • Page 10: Emptying The Water Tank

    5. DRAINAGE EMPTYING THE WATER TANK ⚫ When the tank is full, The unit will make a buzzing sound, and the “Water Full” light will turn on. ⚫ Press the POWER button to turn off the unit. ⚫ Pull on the water tank and simply slide out of the body of the dehumidifier.
  • Page 11: Maintenance

    MAINTENANCE Note: before cleaning and maintaining the machine, be sure to turn off the machine and pull the power plug to prevent electric shock. CLEANING THE AIR FILTER The filter should be cleaned every 2 weeks. Dust collects on the filter and restricts the airflow. The restricted airflow reduces the efficiency of the system and if it becomes blocked it can cause damage to the unit.
  • Page 12: Troubleshooting

    TROUBLE SHOOTING NORMAL OPERATING TEMP. 5°C ≤ to ≤ 35°C When the ambient temp is lower or higher than the normal operating temperature, the dehumidifier stops. When the room temperature is between 5°C ≤ & ≤ 16°C, the compressor automatically defrosts at regular intervals;...
  • Page 13 STORAGE Long-term storage - If you will not be using the unit for an extended period of time (more than a few weeks) it is best to clean the unit and dry it out completely. Please store the unit per the following steps: Press power button to switch off and unplug the unit.
  • Page 14: Technical Specification

    12l / Day SERVICE WARRANTY Prem-I-Air guarantees the product free from defects in materials and workmanship for a period of 1 year. Should this unit be operated under conditions other than those recommended, at voltages other than the voltage indicated on the unit, or any attempts made to service or modify the unit, then the warranty will be rendered void.