Page 1
INSTRUCTION HANDBOOK Electric Lifting Table WARNING Do not use the lifting table before reading and understanding these operating instructions. NOTE: Please check the designation of your present type at the last page of this ...
Page 3
FOREWORD Before operating the lifting table, read this ORIGINAL INSTRUCTION HANDBOOK carefully and understand the usage of the lifting table completely. Improper operation could create danger. This handbook describes the usage of different lifting tables. When operating and servicing the lifting table, make sure, that it applies to your type. Keep this handbook for future reference.
TABLE OF CONTENTS 1. CORRECT APPLICATION ....................4 2. DESCRIPTION OF THE LIFTING TABLE..............5 a. Overview of the main components................5 b. Main technical data ....................6 c. Description of the safety devices and warning labels..........6 d. Identification plate ......................7 3. WARNINGS AND SAFETY INSTRUCTIONS ...............8 4. ...
1. CORRECT APPLICATION It is only allowed to use this lifting table according to this instruction handbook. This table is a mobile lifting table designed to lift or lower a clearly defined load. Do not use this table for other purpose than its intended use. A wrong usage can cause human injuries or can damage equipment.
Main technical data Fig. 2: Technical data Table 1: Main technical data for standard version TYPE ETF 30 ETF 50 ETF 75 ETF D35 Capacity Max table height 1025 1300 Min. table height Table/ platform size (LxBxH) 850x500x50 1010x520x50 1000x510x55 910x500x53 ...
Fig. 3: Safety and warning labels A Capacity sticker (both sides, sample E Brake sticker for illustration only, capacity might be F Sticker to read this instruction different) G Prohibit decal B Sticker finger shearing and crushing H Direction movement marking (both sides) (11) Emergency stop button C Identification plate (ID-plate)
Own mass/ net weight in kg Name and address of the manufacturer IP- Protection code Allowed load distribution Max. operating pressure in MPA 10 Lift category 2 according to EN 1570 Supply voltage in V 11 Rated capacity in kg Nominal power in kW 12 Manufacturing date If sold to the EU, here...
Stop operation if temperature of hydraulic oil is too high. 4. COMMISSIONING, TRANSPORTING, STORAGE/ REASSEMBLING Commissioning For the commissioning following information are relevant: Table 2: Commissioning data Type ETF 30 ETF 50 ETF 75 ETF D35 Commissioning weight app. 140 kg app. 177 kg app.
following points before operation. Remove load from table and when servicing, please use the safety mechanism (14) to prevent table from lowering. DO NOT USE THE TABLE IF ANY MALFUNCTION OR FAULT IS FOUND. HYDRAULIC LEAKAGE CAN CAUSE MALFUNCTIONS AND LOSS IN THE LIFTING FUNCTION.
ETF 30 300 kg ETF 50 500 kg ETF 75 750 kg DO NOT OVERLOAD THE TABLE! ETF D35 350 kg The capacity sticker (A) shall be clearly and permanent visible from the operating position. Working at Height ...
The lifting table is equipped with “maintenance free” sealed liquid acid batteries. o ETF 30/ ETF 75/ ETF D35 4 x 12V 15 Ah / Type BT-12M15AC o ETF 50...
Turn off the lifting table by turning the key switch (12) to the “off”- position. Connect the charger (9) with the included cable to the power socket. Charging starts automatically. The switch of charger turns off automatically, if the battery reaches 80% capacity or exceeds 12 hours in charging condition.
Page 15
For refilling the hydraulic fluid, you need to unscrew the hydraulic power pack and place this vertically. Then you can remove the oil tank and it is possible to check and refill the oil. Assembling must be done in the opposite direction. For this work please call the service.
Page 16
Table 4: Maintenance Logbook Regular Maintenance Logbook Date Name Comments Date Name Comments start start...
9. TROUBLE SHOOTING If the table has malfunctions follow the instructions, mentioned under chapter 7 f. Table 5: Trouble shooting TROUBLE CAUSE REPAIR Faulty wiring Check the wiring referring to the Table does not rise actual wiring diagram. while motor does Battery cord is disconnected.
DECLARATION OF CONFORMITY (valid, if sold within the EU) [GB] CE Declaration of Conformity The signatory hereby declares that the specified machine conforms to the EU Directive 2006/42/EC (Machine Directive) and 2004/108/EEC (Electro-Magnetic Compatibility, EMC) including their amendments as translated into national legislation of the member countries. The signatory is individually authorized to compile the technical documents.
Page 20
og 2004/108/EEC (elektromagnetisk fordraglighet - EMV) inklusiv disses endringer og den tilsvarende rettsforordning til omsetning av nasjonal rett. Hver undertegnede er fullmektig til å sette sammen de tekniske dokumentene. [PL] DEKLARACJA ZGODNOŚCI Z NORMAMI UE Niżej podpisani potwierdzają niniejszym, że opisany tutaj, napędzany określona maszyna spełnia wymagania określone w dyrektywach Europejskich 2006/42/EC (Maszyny) i 2004/108/EEC (Nieszkodliwość...