Sharp SMO1854DS Service Manual page 20

Hide thumbs Also See for SMO1854DS:
Table of Contents

Advertisement

(TROUBLE 3) No microwave oscillation even though fan motor rotates.
CONDITION
No
microwave
oscillation
Check continuity of high voltage
rectifier in forward and backward
Check resistance of primary and
secondary coil of high voltage
Check continuity of magnetron
supplied to RELAY (RY1) coil
CHECK
Check continuity of high
voltage capacitor terminals
with wires removed
direction with DC megger
Connect megger leads to
magnetron terminal and
magnetron body
transformer
with wires removed
Check continuity of filament
terminal of high voltage
transformer
Check D.C. voltage being
RESULT
Continuity
Defective high
Continuity in
Defective high
backward
voltage rectifier
direction
Continuity
0 Ω or ∞
Defective high
No
Continuity
No
Defective high
Continuity
0 V
Defective touch
control circuit
Approx
15 VDC
RELAY (RY1)
19
CAUSE
REMEDY
Replace
voltage
transformer
Replace
Replace
Defective
magnetron
Replace
voltage
transformer
Replace
Defective
magnetron
Replace
voltage
transformer
Replace
Replace
Faulty
contacts or
or open
relay coil

Advertisement

Table of Contents
loading