Fault
Creasing.
and programme ter-
minated.
The programme does
not start.
The length of the pro-
gramme changes dur-
ing the drying cycle.
Pumping noise.
Buzzing noise.
The drying time is too
long.
Cause and troubleshooting
→ "Changing the dryness level", Page 20.
▶
→ "Adjusting the dryness level", Page 20.
▶
Anti-Crease not activated.
Activate the Anti-Crease function.
▶
→ "Buttons", Page 18
Condensation tank filled.
→ "Emptying the condensation container", Page 27.
1.
→ "Inserting the condensation container", Page 28.
2.
→ "Starting the programme", Page 25.
3.
Foreign object is located in the base unit
→ "Opening the base unit", Page 33.
1.
Remove the foreign objects that are present.
2.
→ "Closing the base unit", Page 34.
3.
Childproof lock is activated.
→ "Deactivating the childproof lock", Page 28
▶
has not been pressed.
Press
.
▶
No programme set.
→ "Setting a programme", Page 25.
1.
→ "Starting the programme", Page 25.
2.
The programme operation is optimised electronically.
This may change the programme duration.
Not a fault – no action required.
▶
Condensation pump active.
Not a fault – normal operating noise.
▶
Compressor ventilation active.
Not a fault – normal operating noise.
▶
Fluff filter is soiled.
→ "Cleaning the fluff filter", Page 26
▶
The ambient temperature is greater than 30 °C.
Ensure that the ambient temperature is below 30
▶
°C.
The ambient temperature is lower than 15 °C.
Ensure that the ambient temperature is above 15
▶
°C.
Insufficient air circulation at the appliance's installation
location.
Ventilate the appliance's installation location.
▶
Troubleshooting en