Setting The End Positions - 3T-Components 3T-MOTORS 3T45-E Installation & Operating Instructions Manual

Shutter motors with obstacle detection and electronic limit switches
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS

Setting the end positions:

7
1. Check direction of rotation!
When you press the Up button, the roller shutter must move upwards! If this is not the case, exchange the black and brown wires.
Please program each motor individually!
Automatic mode:
Fixed shaft connectors and stoppers
or angle end rail are
absolutely necessary!
2. Initialization
The engine is delivered from the factory
in Automatic mode:
Allow the roller shutter to move up and down completely once.
> The motor detects the end positions and stops automatically.
Note:
After three further cycles (3x completely up and down), the roller shutter no
longer moves against the end stops, but stops automatically beforehand.
Every 60 cycles, the drive independently checks and corrects the end
positions in fully automatic mode.
Function overview Adjustment cable ESKS:
LED On/Off
Buttons & Function
Up button: Controls the motor upward
Down button: Controls the motor downward
SET button: Select operating mode, initialization, save end position
LED On/Off lights up permanently: Mains operating mode
LED On/Off flashes: Programming mode Electronic motors
or
Up button
Down button
SET button
Manual mode:
Suspension springs and no stoppers.
2. Connecting the ESKS plug
> LED On/Off lights up permanently.
3. Press Down button + SET button simultaneously
> LED On/Off flashes: The ESKS is in the
Programming mode for electronic motors.
4. Initialization
Press the SET button until the shutter is
has briefly moved up and down.
5. Setting the lower end position
Move the curtain to the desired lower end
point. Press the SET button, until the curtain
has moved up and down briefly.
6. Setting the upper end position
Move the curtain to the desired upper end
point. Press the SET button until the curtain
has moved up and down 2x briefly.
Now the end positions are stored.
Reset to factory setting:
Press the SET key for 12 sec until the curtain
moves up and down 3 times briefly.
Now the drive is in the delivery
state and can be reprogrammed!
3T-MOTORS Tubular motors | Installation instructions
2x
3x
9

Advertisement

Table of Contents
loading

Table of Contents