Water System - Scotsman Prodigy Plus A Series Service Manual

Remote low side modular flake ice machine
Hide thumbs Also See for Prodigy Plus A Series:
Table of Contents

Advertisement

FS2330L
Remote Low Side Service Manual

Water System

Water enters the machine through the 3/8" male flare
at the rear of the cabinet, goes to the water reservoir
which it enters through the float valve.
The float valve maintains a constant level of water in
the reservoir and evaporator, as water flows out the
bottom of the reservoir tank to fill the evaporator.
Reservoir overflow or evaporator condensation is
routed to the drain.
Water Level: The correct water level should be
checked when the machine is making ice. Check
the water level in the reservoir and compare it to the
horizontal line molded into the side of the reservoir.
Water Level
The correct level should be between 1/8" above and
1/4" below the line. If needed, bend the float arm up
or down to adjust the water level.
Water Sensor
Water Inlet to Evaporator
December 2022
Page 20
Float Valve
Vented Drain Plug
Drain Tube