6. INSTALLATION GUIDE
(CONT.)
7) Electrical Wiring
Connect the cables to the designated ports on the display as follow (See Figure 8.):
a. Connect the outlet cable of ArrowMAX
b. Connect the inlet cable to port #2 on the display.
c. Connect the flow sensor cable to port #5 on the display.
d. Connect the power adapter cable to the power connector on the display.
Note: Ports #3 and #4 are for potential future upgrades and shall not be connected.
Figure 8: Ports on the Control Display
8) Powering the System
Plug the power adapter into the appropriate GFCI-protected outlet. The display will
turn on with the Acuva logo. Please wait for a few seconds for the device activation
to complete. The device is then ready for operation.
16
• DO NOT PLUG IN CABLES WHEN THE POWER IS ON.
• IT MAY DAMAGE THE UNIT.
HOME reactor to port #1 on the display.