4) Setting the Heater Room Temperature Correction
Depending on the installed environment, the room temperature sensor may require a correction.
The settings may be changed as shown in the table below.
Setting Description
Standard
Lower control
Slightly warmer control
Warmer control
5) Auto Restart
Enable or disable automatic system restart after a power outage.
Setting Description
Yes
No
* Auto restart is an emergency function such as for power failure etc. Do not start and stop the indoor unit by this function in
normal operation. Be sure to operate using the remote controller, or external input device.
6) Indoor room temperature sensor switching function
(Only for Wired remote controller)
The following settings are needed when using the control by Wired remote controller temperature sensor.
Setting Description
No
Yes
* If setting value is "00":
Room temperature is controlled by the indoor unit temperature sensor.
* If setting value is "01":
Room temperature is controlled by either indoor unit temperature sensor or remote controller unit sensor.
7) Cool air prevention
This setting is used to set the fan speed when the compressor stops once the room temperature has reached the set temperature during
heating operation.
Setting Description
Super low
Follow the setting on
the remote controller
(corresponding to
ventilation)
8) External input control
"Operation/Stop" mode or "Forced stop" mode can be selected.
Setting Description
Operation/Stop mode
(Setting forbidden)
Forced stop mode
9) Room temperature control switching
This setting is used to set the room temperature control method when the wired remote controller is selected by the Indoor Room
Temperature Sensor Switching Function.
Setting Description
Control by the sensors
of both the indoor unit
and the wired remote
controller.
Control only by the sensor
of the wired remote
controller
(  . . .Factory setting)
Function Numbe
Setting Value
00
01
31
02
03
(  . . .Factory setting)
Function Number
Setting Value
00
40
01
(  . . .Factory setting)
Function Number
Setting Value
00
42
01
(  . . .Factory setting)
Function Number
Setting Value
00
43
01
(  . . .Factory setting)
Function Number
Setting Value
00
46
01
02
(  . . .Factory setting)
Function Number
Setting Value
00
48
01
- (01 - 28) -