6-2.
HEATING CAPACITY
This table is created using maximum capacity.
MODEL
: AR G24LMLA
AFR
18.3
°CDB
°CDB
°CWB
-15
-10
-5
0
5
7
10
15
20
24
AFR : Air Flow Rate (m
3
/min)
TC : Total Capacity (kW)
IP
: Input Power (kW)
16
TC
IP
-16
6.27
2.75
6.12
-11
7.10
2.97
6.93
-7
7.94
3.12
7.75
-2
8.80
3.05
8.59
3
9.72
3.08
9.49
6
9.56
2.66
9.33
8
9.85
2.66
9.62
10
9.03
2.13
8.82
15
8.29
1.65
8.09
18
8.58
1.65
8.38
Indoor temperature
18
20
TC
IP
TC
IP
2.81
5.97
2.87
3.04
6.76
3.10
3.18
7.56
3.25
3.12
8.38
3.18
3.14
9.26
3.21
2.71
9.10
2.77
2.72
9.38
2.78
2.17
8.60
2.22
1.69
7.90
1.72
1.68
8.17
1.72
- (01 - 11) -
22
24
TC
IP
TC
IP
5.82
2.93
5.67
2.98
6.60
3.16
6.43
3.22
7.37
3.31
7.18
3.38
8.17
3.25
7.96
3.31
9.03
3.27
8.80
3.34
8.87
2.83
8.65
2.88
9.15
2.83
8.91
2.89
8.39
2.26
8.17
2.31
7.70
1.76
7.50
1.79
7.97
1.75
7.77
1.79