5.1
F
/ E
IRING UP
XTINGUISHING
After the initial ignition of the boiler, the Ignition function must be activated. In this mode, the fan will start working to facilitate
ignition (in a still cold boiler). Once the CH temperature rises to 30°C (the so-called fan threshold), the Fan On/ Off function will
appear on the display instead of the Ignition option and the Manual Operation diode will turn off and the boiler will enter the
operating mode. Using the Fan On/ Off function, the fan can be switched on or off (e.g. when adding fuel). Turning off the fan is
indicated by an asterisk on the main screen in the lower right corner of the display. This function allows for safe operation of the
boiler. Never open the furnace door with the fan on. If the boiler reaches a temperature of 35°C, the pump (or both pumps
depending on the operating mode) will start.
5.2
S
CREEN VIEW
In this function, the user can select one of the available main screens of the thermoregulator operation. These are:
•
CH screen (the current boiler operating mode is displayed)
•
Service screen (allows you to view the parameters available in the service menu)
5.3
T
EMPERATURE SETTINGS
5.3.1
CH SET TEMPERATURE
This option is used to set the boiler temperature. The user can change the boiler temperature range from 40
CH can also be changed directly from the main screen of the controller.
5.3.2
DHW SET TEMPERATURE
This option is used to set the set temperature of domestic hot water. The user can adjust this temperature in the range from 35
O
to 60
C.
5.4
W
ORK SETTING
MAIN
MENU
5.4.1
BLOWING FORCE
This function controls the fan speed. The adjustment range is from 1 to 100%, (it can be assumed that these are fan speeds). The
higher the speed, the faster the fan works, where 1% is the minimum fan speed and 100% is the maximum.
5.4.2
FAN IN MAINTAINING
In this function, the user sets the running time and the fan pause time during the operation in the temperature maintaining cycle.
5.4.3
MAINTAINING TIME
This option is used to set the fan idle time during the maintaining period.
CAUTION
Incorrect setting of this option may cause a constant increase in temperature! The maintaining interval should not be
too short.
Blowing force
Fan in maintaining
WORK
SETTING
Maintaining time
Fan speed in maintaining
8
O
O
C to 80
C. The set
O
C