Huawei SUN2000-M3 User Manual page 84

Table of Contents

Advertisement

SUN2000-(20KTL, 29.9KTL, 30KTL, 36KTL, 40KTL)-
M3
User Manual
ID
Name
2011
String
reverse
connecti
on
2012
String
current
backfeed
2021
AFCI
self-
check
failure
2031
Phase
wire
short-
circuited
to PE
2032
Grid loss
Issue 11 (2023-01-10)
Severity
Cause
Major
The PV string polarity is
reversed.
Cause ID 1–8: PV strings 1–
8
Warning
The number of PV modules
connected in series to the
PV string is insufficient. As
a result, the terminal
voltage is lower than that
of other strings.
Cause ID 1–8: PV strings 1–
8
Major
Cause ID = 1, 2
The AFCI self-check fails.
Major
Cause ID = 1
The impedance of the
output phase wire to PE is
low or the output phase
wire is short-circuited to PE.
Major
Cause ID = 1
● Power grid outage
occurs.
● The AC circuit is
disconnected or the AC
switch is off.
Copyright © Huawei Technologies Co., Ltd.
8 Maintenance
Solution
1. Check whether the PV string
is connected to the device in
reverse polarity. If yes, wait
until the PV string current
decreases to below 0.5 A, set
DC SWITCH to OFF, and
adjust the PV string polarity.
2. If the fault persists, reset the
device on the local
maintenance app or WebUI
of the upper-layer controller.
Alternatively, you can turn off
the AC and DC switches, wait
for 5 minutes, and then turn
on the AC and DC switches.
1. Check whether the number of
PV modules connected in
series to the PV string is less
than that of other PV strings.
If yes, wait until the PV string
current drops below 0.5 A,
turn off all DC switches, and
adjust the number of PV
modules in the PV string.
2. Check whether the open-
circuit voltage of the PV
string is abnormal.
3. Check whether the PV string
is shaded.
Turn off the AC output switch
and DC input switch, and then
turn them on after 5 minutes. If
the alarm persists, contact
Huawei technical support.
Check the impedance of the
output phase wire to PE, locate
the position with low
impedance, and rectify the fault.
1. The alarm is cleared
automatically after the power
grid recovers.
2. Check whether the AC circuit
is disconnected or the AC
switch is off.
75

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents