Alarm
Alarm
ID
Name
2086
External
fan
abnormal
2090
Abnormal
active
power
schedulin
g
instructio
n
2091
Abnormal
reactive
power
schedulin
g
instructio
n
2102
Protection
upon
Communi
cation
Failure
Issue 03 (2023-02-15)
Alarm
Possible Causes
Severity
Major
Cause ID = 1
The external fan is
short-circuited, the
power supply is
insufficient, or the
air channel is
blocked.
Major
Cause ID = 1
● The DI input is
abnormal.
● The DI input is
inconsistent with
the
configuration.
Major
Cause ID = 1
● The DI input is
abnormal.
● The DI input is
inconsistent with
the
configuration.
Warning
Cause ID = 1
When the
disconnection of
communication
exceeds the
specified time
threshold, the
device starts the
protection function.
Copyright © Huawei Digital Power Technologies Co., Ltd.
Troubleshooting
1. Shut down the fan, turn off the DC
switch, check whether the fan blades
are damaged, and clear the foreign
matter around the fan.
2. Reinstall the fan, turn on the DC
switch, and wait for the inverter to
start. If the alarm persists after 15
minutes, replace the external fan.
1. Check whether the cables are
connected correctly to the DI ports.
2. On the DI active scheduling screen
under the dry contact scheduling
settings, view the DI signal
configuration mapping table. Contact
the power grid company to check
whether the configurations in the
mapping table are complete and
meet the requirements.
1. Check whether the cables are
connected correctly to the DI ports.
2. On the DI reactive power
scheduling screen under the dry
contact scheduling settings, view the
DI signal configuration mapping
table. Contact the power grid
company to check whether the
configurations in the mapping table
are complete and meet the
requirements.
1. Check whether the communications
cable is connected properly.
2. After communication is restored, the
device will recover upon receiving a
scheduling command.
3. If the Protection upon
Communication Failure function is
not required, disable it.