List of messages after Auto Calibration measurements
Error 30:
Headphones inserted. Remove headphones and re-measure.
Error 31:
SPEAKERS(A/B/A+B/OFF) are off. Re-measure with audio coming out of the SPEAKERS (A/B/A+B/OFF). For details on the front
speaker selection, see
"Selecting the front
Error 32:
No sound was detected from any channel. Is the measurement microphone damaged? Is it connected to the CALIBRATION MIC jack
on the front of this unit?
Error 34:
Front speakers (*) are not installed in the correct position. Left/right of the microphone and speakers may be installed in reverse.
*
The speaker name in this error message depends on the detected symptom.
Error 35:
Center speaker (*) pattern settings and measurement results do not match. Check the center speaker pattern and connection.
*
The speaker name in this error message depends on the detected symptom.
Error 36:
3D position could not be measured. Microphone or microphone stand may be misaligned. Return to the correct position and try again.
If noisy, measure with as little surrounding noise as possible.
Error 37:
No sound was detected from either the left or right surround speakers. Is the power for the wireless speakers that are used as the
surround speakers turned on?
No sound was detected from either the left or right surround back speakers. Is the power for the wireless speakers that are used as
the surr. back speakers turned on?
To output audio from the connected wireless speakers, update software to the latest version. Press [HOME] on the remote for this
unit and select "Setup" to update.
Error 38:
It wasn't possible to measure correctly. Move the speaker or microphone position a little and try again. If noisy, measure with as little
surrounding noise as possible.
Warning 40:
Measurement complete, but it is noisy. It may be possible to measure again, but it is not possible to measure in all environments.
Measure with as little surrounding noise as possible.
Warning 41, Warning 42:
The input from the measurement microphone is excessive. The speaker and microphone may be too close. Place the speaker and
microphone away from each other. If using this unit as a preamplifier, this message may be displayed depending on the connected
power amplifier, but it can be used as it is.
Warning 43:
The subwoofer distance and phase could not be measured. Noise may be the cause. Re-measure in a quiet surrounding environment.
Warning 44:
Measurement finished, but the center speaker (*) positional relationship may be unsuitable. Check the speaker position referring to
"Installing speakers" in the Help Guide.
*
The speaker name in this warning message depends on the detected symptom.
speakers."