9.
As the M.O.L.E.® and test product emerge from the
process, retrieve the sensors from the test product and
lay the Thermal Barrier on a table or flat surface.
10.
Open the Thermal Barrier and if the Record button is
still flashing this means the M.O.L.E.® Profiler is still
logging and it should be stopped.
11.
Remove the M.O.L.E.® Profiler from the Thermal Barri-
er and wait a few minutes for the M.O.L.E.® Profiler to
cool. Handle it carefully, as the case may still be warm.
12.
Disconnect M.O.L.E.® Profiler from the sensors and
place it near the PC that has the MAP installed.
If sensors are removed before the M.O.L.E.®
Profiler has stopped collecting data, it may
cause the data to become distorted.