Changing Parameters At The Operator Level (A); Parameter List At The Operator Level (A) - Dürkopp Adler Class 271 Instruction Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 110

8.2.4 Changing Parameters at the Operator Level (A)

The parameter values at the operator level (see Parameter List 8.2.5) can be changed
as follows.
Turn the mains switch on, do not operate the pedal.
The "Manual Sewing" work mode is active (the LED in the key 5 (P/M)) is dark).
Press the 6 (T/E) key, the LED is lit, sewing is no longer possible.
The first parameter at the operator level is shown in the display.
Example:
NumberMeaning
1
Number of forward stitches in the beginning bartack
3
Number of reverse stitches in the beginning bartack
5
Number of reverse stitches in the end bartack
7
Number of forward stitches in the end bartack
10
Parameter number (hundreds)
11
Parameter number (tens)
12
Parameter number (ones)
14-16 Parameter value
The parameter value can be changed with the L+ or L- key
The parameter number can be changed with the P+ or P- key (hundreds) or with
the S+ or S- key (tens and ones).
Press the 6 (T/E) key, the setting is saved, the operator level A is exited, the LED is
dark and sewing is possible again.

8.2.5 Parameter List at the Operator Level (A)

Parameter
No.
Abbr.
Designation/Function
111
LS
Light barrier compensation stitches
112
LS
Number of stitches to the light barrier mark
by knitted goods
116
SANL
Number of softstart stitches
148
AR
Beginning bartack-double = I, single = II
149
ER
End bartack-double = I, single = II
450
LS/STL Light barrier compensation stitches by short
sewing length
523
RIE/
Change-over fancy-stitch bartack = I,
ZRIE
normal bartack = II
64
Change via:
P+ or P- key
S+ or S- key
S+ or S- key
L+ or L- key
Setting RangePreset
min
max
100R
1
255
6
0
255
0
0
255
2
I
II
I
I
II
I
1
255
6
I
II
II