7.6 Structure and environmental conditions
Item
Material
Color
External dimensions
Mass
Protection rating
Operating temperature and
humidity limits
Storage temperature limits
Product warranty period
7.7 Technical standards
Item
JIS C 1111:2019
Transducer
IEC 60688 :2012
EMC Directive 2014/30/EU
EN 61000-6-2, EN 61000-4-2, -3, -4, -5, -6, -8, -11
EN 61000-6-4, EN 55011 classA, Group1
Low Voltage Directive 2014/35/EU
CE marking
EN 61010-1
RoHS Directive 2011/65/EU+(EU)2015/863
EN IEC 63000
IEC 61010-1
Safety
Measurement Category Ⅲ, Maximum use voltage:300V, Pollution degree 2
8. Input and output relationship
OUTPUT
[V][mA]
5
1
2.5 0.5
0
0
45
55
45
50
55
60
BOX:ABS(V-0), Terminal board:ABS(V-0), Terminal cover:Polycarbonate
Munsell N1.5 (Black)
40×120×130mm (W×H×D)
Approx. 250g
IP30
-10 to 55℃ , 5 to 90% RH (Non condensing)
-40 to 70℃
One year period
OUTPUT
[V][mA]
5 20
3 12
1
4
65[Hz]
INPUT
55[Hz]
65[Hz]
Specification
Specification
45
55
65[Hz]
45
50
55[Hz]
55
60
65[Hz]
10
INPUT
Q-222-035