I N S T R U C T I O N M A N U A L
G F B 2 T O W E R
GeoFilter GFB2 Tower 6-2, GeoFilter GFB2 Tower 9-3,
GeoFilter GFB2 Tower 12-4
www.geovent.com
Version 1.0
03.11.21

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GeoFilter GFB2 Tower 6-2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Geovent GeoFilter GFB2 Tower 6-2

  • Page 1 I N S T R U C T I O N M A N U A L G F B 2 T O W E R GeoFilter GFB2 Tower 6-2, GeoFilter GFB2 Tower 9-3, GeoFilter GFB2 Tower 12-4 www.geovent.com Version 1.0...
  • Page 3: Table Of Contents

    Do not modify the product or use spare parts from other suppliers than Geovent, as this may hamper the product When the manual has been read and understood in full, and the function.
  • Page 4: Machine Oveview

    When you change the filter cartridges, follow the instruc- Automatic control: Filter regulation with digital dis- tions in chapter 7.3. play for adjusting cleaning time, cleaning interval, and shot down While opening, cleaning and maintaining the unit or cleaning. while changing parts, disconnect the unit from the mains supply and secure it from being restarted.
  • Page 5: Transport, Handling And Storage

    Max. 40°C 5.2 Installation Higher temperatures require the use of special motors. Contact Geovent for more information. For error-free performance, the product should be in- stalled indoors, e.g. in a well-ventilated room. We do not recommend outdoor installation. If indoors installation is Name plate not possible, it must at least be installed under a roof.
  • Page 6 The following installation should be performed by a trained service engineer. Procedure: 1. Place the product upon solid, flat foundation (e.g. a concrete floor) and anchor it. Allow space to perform filter changes. 2. Attach the product to circular ventilation tubes on both the clean side and the dirty side (the bottom tube con- nection is always the dirty side).
  • Page 7 6.0 Timer control panel 6.1 Operating the filter The filter is delivered as standard with timer control, but it can be beneficial in some situations to allow the clea- ning frequency to be controlled as a function of the filters pressure differentials.
  • Page 8 Cleaning function with off fan The function allows one or more cleaning sequences (the number selected in F13), when the fan is turned off. The cleaning time is always as selected in F02, while the pause time is selected in F14. The display alternately shows the number of seconds to cleaning and the code ”PCC”.
  • Page 9 Alarms: The unit runs a number af checks during the start-up cycle and during normal operation. The possible alarms and respective solutions are shown in the following table. Alarm Description Action 24Vdc, switch the device off and move the ac/dc jumpers to dc. F05 set to 24Vdc - ac jumper detected.
  • Page 10 Connections diagram Connection diagram Connection diagram                     Supply voltage: Supply voltage: 230V AC 230V AC Alarm relay: Alarm relay: No (Max 3A@250V AC) No (Max 3A@250V AC) Fan input: Fan input: Open Open = Fan off = Fan off  ...
  • Page 11 2.1.3 Differential pressure control (OPTION) Proportional mode F01=3 With the proportional mode, the economiser will work in full autonomy, initially setting the DP_Start threshold (F08), activation time (F02) and pause time (F03). When the Start Cleaning threshold is exceeded, the solenoid valves are automatically activated in sequence.
  • Page 12 List of Functions F14: Pause time betwen cleaning cycles after fan stop. F01: Activation time. Possible values: 001 - 999. Step 1 Possible values: Default = 10 0 - Manual (∆p excluded) 1 - Automatic (Default)(∆p included) F15: Service timer. 2 - Automatic with forced cycle (∆p included) Possible values: 001 - 999.
  • Page 13 Alarms The unit runs a number af checks during the start-up cycle and during normal operation. The possible alarms and respective solutions are shown in the following table. Alarm Description Action 24Vdc, switch the device off and move the ac/dc jumpers F05 set to 24Vdc - to dc.
  • Page 14: Control, Test And Maintenance

    6.2 When the product has been installed Periodic maintenance of the filter: When assembly of the filter is complete, installed cor- • All electronic parts should be checked yearly rectly and ready for use, there will not be any interaction •...
  • Page 15 Security Check: 1. Check that all 4 locks are tight so they cannot be loosened by hand. 2. Pull the handle, to be sure thet it is locked. 7.3 Replacing the filter cartridges The filter medium should be changed after about 4.000 – 8.000 hours of operation or after a maximum of 4 years.
  • Page 16: Cleaning

    The filter self-cleans automatically as a compressed air - Increase after-cleaning. pulse is sent down through the filter cartridges, causing - Use Prekote. Contact Geovent for more information. the particles on the textile of the filter to be blown off and collected in the bucket below.
  • Page 17: Dismantling, Disabling And Scrapping

    10.0 Dismantling, disabling and scrapping Deactive the product by disconnection the electrical mains. Dismantle the compressed air pipes and other tubes etc. When you dispose of the product you should dismantle the filter elements as described in chapter 7.3.It is very important that the instructions of this manual is followed in order to avoid contamination of people and the en- vironment!
  • Page 18 11.0 Multi coupling diagram...
  • Page 19 Outlet Inlet GFB2 Tower 9-3 Model/Dimension [mm] Inlet Outlet Weight Casing GFB2 Tower 6-2 3040 ø315np ø400np 290 kg Galvanized GFB2 Tower 9-3 1060 3100 ø400np ø500np 360 kg Galvanized GFB2 Tower 12-4 1230 3150 ø500np ø500np 480 kg Galvanized...
  • Page 20: Liability

    Model: GFB2 Tower 3-1, GFB2 Tower 6-2, No claims can be made against Geovent A/S in relation GFB2 Tower 9-3, to loss of earnings or consequential loss as a result of GFB2 Tower 12-4 defects on products from Geovent.
  • Page 21: Spare Part List

    14.0 Spare part list Varenr. Beskrivelse Timer control panel GFB2 TOWER 92-214 (mounted as standard) Differential pressure control panel 92-214B GFB2 TOWER 93-VNP-208 Solenoid valve 24V FT/11 – 99,9% at 0,3µm (grinding 15-480FL dust / All-Round) FT/11 - 99,9% at 0,3µm ALUTEC 15-480AFL (All-Round) FT/13 –...
  • Page 24 HOVEDGADEN 86 • DK-8831 LØGSTRUP (+45) 8664 2211 • salg@geovent.dk...

This manual is also suitable for:

Geofilter gfb2 tower 9-3Geofilter gfb2 tower 12-4Geofilter gfb2Geofilter gfb2 3-1Geofilter gfb2 6-2Geofilter gfb2 9-3 ... Show all