heater. Keep hands and feet away from any
portion of the heater being raised.
WIRING
The required voltage and amperage for each
heater is listed in the SPECIFICATIONS section
of the manual and are also listed on the heater
identification plate attached to the heater. If the
heater needs to be operated on a voltage other
than that indicated by these decals, consult the
factory for instructions. If a voltage change has
been made, re-label the heater as such. For
Safety reasons, as well as preventing damage
to the heater, NEVER leave the wrong decal in
place. No information is better than the wrong
information. The heater must be wired (at every
installation) according to the voltage and
amperage required. A qualified electrician
must
wire
the
heater
according to the wiring diagram and local,
state, and national codes. The heater must
be electrically grounded in compliance with
the National Electrical Code, ANSI/NFPA 70
and CSA C22.1, Canadian Electrical Code
Part I.
GAS CONNECTIONS AND
SUPPLY
WARNING
Only qualified gas fitting personnel shall
connect or disconnect fuel supply lines to
supply tanks and or gas mains and the
heater gas inlet manifold.
All unions and valves must be checked for
tightness and proper operation before the initial
start-up of the heater. Use Sherlock 5-second
leak (of the proper temperature) or soapy water
on all connections to be sure they are tight.
Replace
or
tighten
necessary.
Tel: (905) 793-2525 | Fax: (905) 793-8768 |
pg. 5
appropriately
any
connection
as
CAMPO EQUIPMENT CO. LTD. (ECOBLAZE)
6 Carson Court, Brampton, ON, CANADA, L6T 4P8
The supply gas hose being used must be
protected from traffic, building materials,
and contact with hot surfaces both during
usage and while in storage.
The supply gas hose shall be visually
inspected prior to each use of the heater. If
it is evident there is excessive abrasion or
wear, or the hose is cut, it must be replaced
prior to the heater being put into operation.
The supply gas hose must be replaced with
a manufacture's authorized replacement
part only.
See the Service Parts section of this manual
for the appropriate replacement part.
OPERATING GAS PRESSURES
Minimum inlet pressure - 10 inches W.C (0.36
PSI) Maximum inlet pressure – 14 inches W.C
(0.50 PSI))
OPERATING INSTRUCTIONS
Pre-Start Checklist
Before attempting to start the Blaze DF2500,
several important checks of the heater and
heater system are critical to safe, efficient, and
dependable usage. Many potential problems
can be avoided by proper maintenance and
attention. The heater should be inspected
before each use, and at least annually by a
qualified service personnel.
1. Familiarize yourself with this Operation /
Service Manual.
2. Check the entire heater for any sign of
physical damage.
3. Check for obstructions to the air intake and
discharge of the heater. Remove anything
that will obstruct or restrict airflow. The
heated work area must be ventilated to
ensure that all air present in the workspace
can be displaced continuously with fresh
heated air. The heater air intake must be