This Operator's Service Manual is intended to
familiarize you with the operation of and
necessary service information for the
BLAZE DF2500 gas fired model. Please read
this manual thoroughly before operating the
Blaze DF2500.
This manual uses the words WARNING,
CAUTION, and NOTE to emphasize certain
information.
WARNING identifies personal
safety related information; therefore, be sure to
read the directive because it deals with the
possibility of personal injury.
identifies heater-related information; therefore,
be sure to read the directive because it deals
with the possibility of damaging part or parts of
the
Blaze
DF2500.
supplementary information worthy of attention.
This manual covers operating instructions,
operator related maintenance instructions,
specifications, and service information. This
manual should be considered a permanent part
of the Blaze DF2500 and must remain with the
heater at the time of resale. If additional service
information is desired, either contact your local
dealer or write or phone:
CAMPO EQUIPMENT CO.LTD.
(ECOBLAZE)
6 Carson Court
Brampton, ON,
Canada L6T 4P8
Tel: (905)793-2525
Fax: (905) 793-8768
www.campoequipment.com

LIMITED WARRANTY

Campo Equipment CO.LTD and accessories
are warranted to the original retail purchaser.
No warranty is transferable to any subsequent
owner. The warranty period is one year from
the date of purchase. The warranty covers all
defects in material and workmanship insofar as
they are of Campo Equipment CO. LTD ,
manufacture. This warranty is limited to the
Tel: (905) 793-2525 | Fax: (905) 793-8768 |
pg. 3
CAUTION
NOTE
identifies
CAMPO EQUIPMENT CO. LTD. (ECOBLAZE)
6 Carson Court, Brampton, ON, CANADA, L6T 4P8
furnishing of new parts only, in the event the
original part is determined to be defective by
Campo Equipment CO.LTD.
The warranty does not include transportation
costs, labour for inspecting, repairing, or
replacing original parts, or consequential
damages. It also does not cover any damage
because of negligence, accident, misuse, or
abuse. Campo Equipment CO.LTD shall not
be liable for delays caused by defects, for
consequential damages, or for any other
damages, charges, or expenses of any nature.
All parts not manufactured by Campo
Equipment CO.LTD. are warranted insofar as
warranted by the manufacturer of such parts.

SPECIFICATIONS

Model Number ....................................DF2500
Width.....................................31.50" (80.01cm)
Length....................................... 111" (281.94 cm)
Height ......................................78.45"(199.26 cm)
Weight .........................1287.00 lbs. (583.77Kg)
Supply panel................23.125"x27" (Rectangular)
Blower Motor ............................10Hp (7.4 Kw)
Heated Air Output.....14737 CFM (417.30 m³/min)
Manifold Pressure" W.C...........2.5" LP and 5.6" NG
High pressure switch to be adjusted for manifold
pressure
Minimum/Maximum Supply Pressure "W.C...10/14
Pilot Pressure .....................................3.6" W.C
Maximum BTU Input ........................ 2,500,000
Kcal/h ................................................629989.4
Minimum BTU Input LP............................615938
Kcal/h ................................................155213.8
Minimum BTU Input NG...........................553197
Kcal/h ................................................139403.3
Required Voltage:
208v to 240v 1Phase or 3 phase
Full Load Amps:
1 Phase 24 amps @ 230v
3Phase 17 amps @230v
This unit is equipped with constant voltage
system. It is activated when voltage is lower
than 208v or higher than 235v.
Minimum 4 X 420lb cylinders are to be used.