Cylinder supply system must be arranged to
provide for vapor withdrawal from the operating
cylinder.
HEATER USAGE
The primary intended use of this heater is to
provide temporary heating for buildings under
construction, alteration or repair.
VENTILATION INFORMATION
DF series heaters require a constant intake
supply of clean, fresh air.
WARNING
The flow of combustion or ventilation air
must not be obstructed in any manner.
WARNING
The heated air MUST NOT be re-circulated
through the heater. The heated work area
must be ventilated to ensure that all air
present in the workspace can be displaced
continuously with fresh heated air.
WARNING
If dizziness or drowsiness is experienced by
any personnel, evacuate the area. Check
the oxygen level in the heated workspace
and make corrections to the ventilation
system as needed.
CLEARANCE FROM
COMBUSTIBLE MATERIALS
Combustible materials and materials which
give off an explosive or volatile vapor must not
be stored or located in the main discharge air
stream of the heater. Since all materials have
a different flash point, it is imperative that the
discharge air temperature be checked at the
location where any combustible material will be
stored. Make sure the air temperature is well
below the material flash point.
Under
no
circumstance
combustible material be stored in the
airstream within 15 feet (4.57 m) of the air
Tel: (905) 793-2525 | Fax: (905) 793-8768 |
pg. 4
should
any
CAMPO EQUIPMENT CO. LTD. (ECOBLAZE)
6 Carson Court, Brampton, ON, CANADA, L6T 4P8
discharge port or within 6" (15.2cm) of the
top, sides or ends of the heater.
WARNING
This heater must be placed at least 10 Ft
(3.05M) from any LP-Gas Container. The
discharge air stream of this heater must not
be directed toward any LP-Gas container
within 20 Ft (6.1M).
WARNING
Do not use this heater in a space where
gasoline or other liquids having flammable
vapors are stored or used.
WARNING
Do not use this heater in a space where
gasoline or other liquids having flammable
vapors are stored or used.
CODES
When installing this heater on a job site, the
installation must conform to all local codes or in
the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1/NFPA 54 and
National Gas and Propane Installation Code,
CSA B149.1 if the unit is to burn natural gas.
The installation must conform to all local codes
or in the absence of local codes, with the
Standard for the Storage and Handling of
Liquefied Petroleum Gases ANSI/NFPA 58 and
National Gas and Propane Installation Code,
CSA B149.1 if the unit is to burn vapor propane.
The installation must be inspected prior to the
first start-up of the heater.
LEVELING HEATER
The heater should be installed on a surface that
is as level as possible. Insure that the wheels
are locked, and heater does not rock after
leveling the heater. If the heater is not leveled
proper it will not work.
WARNING
Do not block the heater too high of the
ground. Also, use care when leveling the
www.campoequipment.com