Westmed HS-403 Instruction Manual

Single-hand tourniquet

Advertisement

Available languages

Available languages

Quick Links

Gebrauchsanweisung
Instruction manual
Einhandvenenstauer
Single-hand tourniquet
Please read these instructions for use carefully
EN
and completely before use, and observe the care
instructions.
The tourniquet is used for blood staunching for intravenous punctu-
ring of vessels for the purpose of blood sampling or the insertion of
intravenous access. In addition, the tourniquet can also be used in
an emergency to stop acute bleeding. Observance of all the informa-
tion in these operating instructions and the relevant regulations and
guidelines is part of the intended use. Any other use is not as inten-
ded, and the manufacturer is not liable for any resulting damage!
This product may only be used by authorized specialist personnel!
Intended patient group:
Adults, children, infants, and babies.
Safety instructions
Keep the tourniquet out of reach of non-medically qualified
persons.
Check the complete tourniquet before use to ensure that it is
not defective.
Do not use the product near or directly on the neck. Such use
is associated with a fatal risk of strangulation and must be
avoided at all costs.
Art. No.: 5810033
Manufacturer No.: HS-403
MDD 93/42/EEC
EN 980:2008;
EN 1041:2008;
ISO 13485:2016;
ISO 14971:2007
WESTMED distributed by
Fleischhacker GmbH & Co. KG
An der Silberkuhle 18
58239 Schwerte, Germany
Tel.: +49 2304 9310
HONSUN (NANTONG) Co., Ltd
No. 8 Tongxing Road Economic
& Technological Development Area,
226009 Nantong City,
Jiangsu Province, P. R. China
Shanghai International
Holding Corp. GmbH (Europe)
Eiffestraße 80, 20537 Hamburg
Germany, SRN: DE-AR-000000001
MD
Do not position the closure directly on a pacemaker and
never use it in an MRI.
Before using the device for the first time, and after each use,
it should be cleaned to prevent germ colonization or germ
transmission. In case of contamination with secretions, other
body fluids, or toxic substances, please follow the internal
hygiene regulations and, in case of doubt, dispose of as
special waste.
Automatic cleaning or disinfection is not possible. Please
follow the cleaning and disinfection instructions.
Immediately after carrying out the medical treatment,
please open the cap as quickly as possible by pressing the
multifunction clip. Avoid uncontrolled opening.
Dispose of the tourniquet if there is visible wear on the
band/closure.
Handling
Position the tourniquet at the desired point on the limb.
The "click" when closing the multifunction clip signifies a
secure connection. Adjust the desired tourniquet pressure by
tightening the opposite end of the strap. Avoid pinching or
squeezing the skin. To release the tourniquet immediately,
press the top release button on the multifunction clip.
Cleaning and disinfection
Please follow your internal hygiene procedures to reduce the risk
of cross-contamination. After application to a patient's skin, the
tourniquet should be cleaned and disinfected with a 70% alcohol
solution (e.g., with soaked wipes). Observe the exposure times of
the product used.
Disposal
The product must be disposed of in accordance with local regulations.
Storage and transport
The tourniquet must be stored and transported in such a way that it
is protected from dust, moisture, and contamination.
Maintenance and service
The end of product life is normally determined by wear and damage
from use. Damaged parts must be replaced! For possible repairs,
please contact your dealer.
Warranty
If the product is handled correctly and our instructions for use are
observed, the statutory warranty of two years commencing on the
date of sale applies.
All information without guarantee – subject to change.

Advertisement

loading
Need help?

Need help?

Do you have a question about the HS-403 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Westmed HS-403

  • Page 1 Art. No.: 5810033 • Do not position the closure directly on a pacemaker and Manufacturer No.: HS-403 never use it in an MRI. • Before using the device for the first time, and after each use, MDD 93/42/EEC it should be cleaned to prevent germ colonization or germ EN 980:2008;...
  • Page 2 Bitte lesen Sie diese Gebrauchsanweisung vor der Bedienung Benutzung sorgfältig und vollständig durch und • Positionieren Sie die Stauschlinge an der gewünschten Stelle beachten Sie die Pflegehinweise. der Gliedmaßen. Das „Klicken“ beim Schließen des Multi- funktionsclips signalisiert eine sichere Verbindung. Durch Der Venenstauer wird zur Blutstauung für das intravenöse das Anziehen des gegenüberliegenden Bandendes stellen Punktieren von Gefäßen zwecks Blutentnahme oder Legen eines...

This manual is also suitable for:

5810033