Mounting the Controller
2-6-2
Light Source
White Balance
Depending on the environment or the kind of light, the image read by the Camera may
appear tinted, even if it is white.
For correct measurement, the sensitivity of R.G.B. must be adjusted so that the
image will really appear in white in accordance with the light source. This is called the
adjustment of white balance.
Note Adjust the white balance before setting the light and adjusting the image.
Refer to White Balance in the F400 Color Vision Sensor Operation Manual.
2-7
Mounting the Controller
The Vision Mate Controller can be mounted to DIN Track or a flat surface.
2-7-1
Mounting to DIN Track
The Vision Mate Controller can be easily mounted to or removed from 35-mm DIN
Track.
PFP-M End Plate
(OMRON)
The following DIN Tracks are available from OMRON.
PFP-100N
PFP-50N
PFP-100N2
Mounting the Controller
Hook the Controller into the DIN Track as shown in the diagram and then press in at
the bottom until the Controller locks into place.
Model
1 m
50 cm
1 m
Section
DIN Track
Length
2-7
13