X1-Smart Series
User Manual
6.0 kW - 8.0 kW
Any corporation or individual should not plagiarize, partially or fully copy (including

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the X1-Smart Series and is the answer not in the manual?

Questions and answers

Summary of Contents for SolaX Power X1-Smart Series

  • Page 1 6.0 kW - 8.0 kW SolaX Power Network Technology (Zhejiang) Co., Ltd. Copyright Declaration The copyright of this manual belongs to SolaX Power Network Technology (Zhejiang) Co., ADD.: No. 288, Shizhu Road, Tonglu Economic Development Zone, Ltd.. Any corporation or individual should not plagiarize, partially or fully copy (including Tonglu City, Zhejiang Province, 310000 P.
  • Page 2: Table Of Contents

    Contents Contents 1 Note on this Manual 1.1 Scope of Validity 1.2 Target Group 1.3 Symbols Used 2 Safety 2.1 Appropriate Usage 2.2 Important Safety Instructions 2.3 Explanation of Symbols 2.4 EC Directives 3 Introduction 3.1 Basic Features 3.2 Terminals of Inverter 3.3 Dimension 4 Technical Data 4.1 DC Input...
  • Page 3: Scope Of Validity

    1 Notes on this Manual 7.1 Trouble Shooting 7.2 Routine Maintenance 1.1 Scope of Validity This manual is an integral part of X1-Smart Series. It describes the assembly, installation, commissioning, maintenance and failure of the product. Please read it 8 Decommissioning carefully before operating.
  • Page 4: Safety

    Over-voltage protection with surge arresters should be provided when the PV power system is installed. The X1-Smart Series are PV inverters which can convert the DC current of the PV The grid connected inverter is fitted with SPDs in both PV generator into AC current and feed it into the public grid.
  • Page 5: Important Safety Instructions

    Only touch the lower enclosure lid during operation. installation guide. It contains no user-serviceable parts. See Warranty for instructions on obtaining service. Attempting to service the X1-Smart Series inverter yourself may result in a risk of electric shock or fire and will void Caution! your warranty.
  • Page 6: Explanation Of Symbols

    Safety Safety PE Connection and Leakage Current 2.3 Explanation of Symbols This section gives an explanation of all the symbols shown on the inverter and • All inverters incorporate a certified internal Residual Current Device(RCD) on the type label. inorder to protect against possible electrocution and fire hazard in case of amalfunction in the PV array, cables or inverter.There are 2 trip thresholds for Symbols on the Inverter the RCD as required for certification (IEC 62109-2:2011).
  • Page 7: Ec Directives

    Thanks for your purchasing with SolaX X1-Smart Series inverter. The X1- maintaining the inverter, otherwise personal injury or death may occur, and Smart Series inverter is one of the finest inverters on the market today, the inverter will be damaged.
  • Page 8: Dimension

    Introduction Technical Data 4. Technical Data Object Description 4.1 DC Input DC Switch (optional) DC Connector RS485/Meter(optional)/DRM(optional) X1-6.0-T-D/ X1-7.0-T-D/ X1-8.0-T-D/ Model AC Connector X1-6.0-T-N X1-7.0-T-N X1-8.0-T-N Waterproof Valve Max. PV array power [Wp] 3000/4000 3000/5000 3000/6000 USB for Upgrade Max. DC voltage [V] DONGLE for WiFi/LAN/GPRS Nominal DC operating voltage [V] Grounding Screw...
  • Page 9: Efficiency, Safety And Protection

    6.0 kW - 8.0 kW Quick Installation Guide X1-Smart Series 6.0 kW-8.0 kW Copyright Declaration The copyright of this manual belongs to SolaX Power Network Technology (Zhejiang) Co., Ltd.. Any corporation or individual should not plagiarize, partially or fully copy (including 4.4 General Data software, etc.), and no reproduction or distribution of it in any form or by any means shall be...
  • Page 10: Installation Precaution

    5.3 Installation Precaution 5.4 Installation Steps Ø Preparation X1-Smart Series inverter is designed for outdoor installation (IP 65). Make sure the installation site meets the following conditions: Below tools are needed before installation. Not be exposed to glare. Not in areas where highly flammable materials are stored.
  • Page 11: Connection Of The Inverter

    5.5.1 The Main Steps to Connect to the Inverter PV String Connection Ø X1-Smart series inverter have a couple of PV connectors which can be connected in series into 2-strings PV modules. Please select PV modules with excellent PV array Inverter function and reliable quality.
  • Page 12 - Remove the cable nut (with rubber insert) from the back shell. Ø Grid Connection X1-Smart series inverter are designed for single phase grid. Voltage range is 220/230/240 V, frequency is 50/60 Hz. Other technical requests should comply e) Slide the cable nut and then back shell onto the cable.
  • Page 13 Installation Installation Selection of Fuses and Cables Note! Main cable(AC line cable) shall be short circuit protected and thermal overload If the AC cable you choose is 16 mm or larger, you need protected. to break the connection between the two rubber rings Always fit the input cable with fuse.
  • Page 14 Step1. Prepare a communication cable (without sheath) and insert the com- munication cable through the cable connector which can be found A meter can communicate with the X1-Smart series inverter through this in the accessories package . interface, then you can: Step2.
  • Page 15 Installation Installation Step1 Ø CT Connection: Step2 cable connector The current sensor measures the current on the phase wire that runs between communication cable the inverter and the grid. CT connection diagram RJ45 plug Step3 Electrical Load grid Home Electric meter Important notice: The arrow on the CT RS485/Meter/DRM port must point to the public grid side.
  • Page 16 Installation Installation Upgrade CT Connection Steps: User can update the inverter system through a U-disk. NOTE! • Do not place the CT on the N Wire or the earth wire. • Do not place the CT on the N and L wire simultaneously. Warning! •...
  • Page 17: Run The Inverter

    Installation Installation Ø 3) Then insert U-disk into the Upgrade port on the bottom of the Start inverter inverter. Then turn on DC switch or connect the PV connector, the LCD Inverter will start automatically when PV panels generate enough energy. will show a picture as below.
  • Page 18: Operation Method

    Operation Method Operation Method 6. Operation Method 6.2 LCD Function Please refer to the inverter for the most updated structure. 6.1 Control panel Menu structure Grid Safety Status Solar Date Time New Password Settings Password Power Factor P(U) Function Power Limits Inverter Yield History Meter Energy...
  • Page 19: Lcd Operation

    Operation Method Operation Method 6.3 LCD Operation a) Grid This status shows the current grid condition such as voltage, current, output Ÿ LCD Digital Display power and the local consumed power. Pout measures the output of the The main interface is the default interface, the inverter will automatically inverter, Pgrid measures power export to or import from grid.
  • Page 20 Operation Method Operation Method Password c) New Password The default password is “0000” for end user, which only allows the user to Installer can set the new password here. We need to increase or decrease the review the current setting and some easy setting. If professional change is word by pressing up or down button.
  • Page 21 Operation Method Operation Method Reactive power control, Reactive standard curve cos φ = f(P) f )P(u) Function The device is suitable for Australia if the “Enable” is chosen. For VDE ARN 4105, curve cos φ (p) should refer to curve A. Default values of setting are as shown in curve A.
  • Page 22 Operation Method Operation Method i) DRM Function m) Start guide User can choose whether using the DRM function or not. This interface makes user set initial setting of the inverter again possible. Start Guide DRM Function >Start >Mode Select Disable j) Reset energy User can reset the energy record here.
  • Page 23: Troubleshooting

    Press up and down button to review parameter. Press“ESC” to return to History. This section contains information and procedures for solving possible problems with X1-Smart series inverters, and provides you with Error Logs troubleshooting tips to identify and solve most problems that could occur >...
  • Page 24 Troubleshooting Troubleshooting AC10Minute overvoltage Fault AC10M Volt Fault System will reconnect if the utility is back to normal. Or seek help from us. Grid Frequency out of range ● If your inverter's information panel is not displaying a Fault light, check the following list to make sure that the present state of the installation allows proper operation of the unit.
  • Page 25: Routine Maintenance

    Troubleshooting Decommissioning 8. Decommissioning 7.2 Routine maintenance Inverters do not need any maintenance or correction in most condition, but if 8.1 Dismantling the Inverter the inverter often loses power due to overheating,this can be the following reason: Disconnect the inverter from DC Input and AC output. ●...
  • Page 26: Disclaimer

    Warranty Registration 9. Disclaimer Form The X1-Smart series inverters are transported, used and operated For Customer (Compulsory) under limited condition, such as environmental, electrical etc. SolaX shall not be liable to provide the service, technical support or compensation under conditions listed below, including but not...
  • Page 27 PLEASE REGISTER THE WARRANTY IMMEDIATELY AFTER INSTALLATION! GET YOUR WARRANTY CERTIFICATE FROM SOLAX! KEEP YOUR INVERTER ONLINE & WIN SOLAX POINTS! Open your Wait for the camera app camera to and point recognize your device the QR code at the QR code Notification Click the notification banner...