Boston Scientific Rotablator Directions For Use Manual

Boston Scientific Rotablator Directions For Use Manual

Rotational angioplasty system console

Advertisement

Console
Consola
Console
Konsole
Console
Console
TM
Kontakt den nærmeste Boston Scientific
kundeserviceafdeling, hvis en dansk kopi af
brugsanvisningerne ønskes. Spørg efter reservedel nr.:
90185046-02 Rev. B
ÅðéêïéíùíÞóôå ìå ôï ãñáöåßï åîõðçñÝôçóçò ôçò
Boston Scientific áí ïé Ïäçãßåò ×ñÞóçò áðáéôåßôáé íá
åßíáé óôá ÅëëçíéêÜ. ÆçôÞóôå ôïí áñéèìü áíôáëëáêôéêïý:
90185046-03 Rev. B
Entrar em contacto com o escritório para atendimento de
clientes da Boston Scientific se uma cópia das instruções
para utilização em português for necessária. Pedir pela
brochura número: 90185046-04 Rev. B
Kontakta Boston Scientific kundtjänst om ni behöver ett
exemplar av en svensk bruksanvisning. Fråga efter del
nummer: 90185046-05 Rev. B
3
Directions for Use
9
Instrucciones de uso
16
Mode d'emploi
23
Gebrauchsanweisung
30
Istruzioni per l'uso
37
Gebruiksaanwijzing
44

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rotablator and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Boston Scientific Rotablator

  • Page 1 åßíáé óôá ÅëëçíéêÜ. ÆçôÞóôå ôïí áñéèìü áíôáëëáêôéêïý: 90185046-03 Rev. B Entrar em contacto com o escritório para atendimento de clientes da Boston Scientific se uma cópia das instruções para utilização em português for necessária. Pedir pela brochura número: 90185046-04 Rev. B Kontakta Boston Scientific kundtjänst om ni behöver ett...
  • Page 3 Rotablator System. • Turbine Pressure Gauge: Located above the turbine pressure control knob, • The Rotablator System should not be used adjacent to or stacked with other the pressure gauge displays the pressure of the compressed gas being equipment and that if adjacent or stacked use is necessary, the Rotablator supplied to the advancer gas turbine.
  • Page 4: Rear Panel

    (approximately 50,000-90,000 the Rotablator Console via a supply hose (provided with the console). The gas RPM) of the Rotablator™ Burr for use during intraprocedure exchange of cylinder is shown for illustration only, and is not of the recommended size.
  • Page 5: Appendix A - Symbol Translation Key

    Do not set on drapes or bedding. Turbine pressure increases with clockwise rotation. 2. Splash The Rotablator Console is designed to be placed outside of the sterile field. Fiber optic connector. Care should be taken to protect the console from splash and ingress of liquids which may cause damage to internal components.
  • Page 6: Appendix B - Service And Maintenance Information

    Verify that all screws are in place on covers. Hold console in both hands and shake in two different directions to verify that there is no loose The Rotablator Rotational Angioplasty System is designed to be operated from hardware inside the console.
  • Page 7: Appendix D - Electronic And Electromagnetic Guidance

    Electromagnetic Guidance Guidance and manufacturer’s declaration - electronic emissions The Rotablator System is intended for use in the electromagnetic environment specified below. The customer or the user of the Rotablator System should assure that it is used in such an environment.
  • Page 8: Warranty

    TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Rotablator System is used exceeds the applicable RF compliance level above, the Rotablator System should be observed to verify normal operation.
  • Page 9 Boston Scientific International S.A. 55 avenue des Champs Pierreux TSA 51101 92729 NANTERRE CEDEX FRANCE Boston Scientific Corporation One Boston Scientific Place Natick, MA 01760-1537 USA Customer Service 888-272-1001 © 2007 Boston Scientific Corporation or its affiliates. All rights reserved. 90185046-01...

Table of Contents