Fluke CableAnalyzer DTX-1500 Technical Reference Handbook page 154

Hide thumbs Also See for CableAnalyzer DTX-1500:
Table of Contents

Advertisement

DTX-1500 CableAnalyzer
Technical Reference Handbook
Parameter
Dynamic range
Amplitude resolution
Frequency range and
resolution
Dynamic Accuracy NEXT
Dynamic Accuracy ACR-F
9-12
Table 9-2. Level IIIe Accuracy Performance Parameters per IEC Guidelines
Baseline Field Tester
3 dB over test limit
PPNEXT and FEXT 65 dB
PS NEXT and FEXT 62 dB
0.1 dB
1 MHz to 31.25 MHz: 125 kHz
31.25 MHz to 100 MHz: 250 kHz
100 MHz to 250 MHz: 500 kHz
250 MHz to 500 MHz: 1 MHz
± 0.75 dB
± 1.0 dB (FEXT dynamic accuracy is tested to ± 0.75 dB)
Field Tester with Level IIIe
Permanent Link Adapter
Field Tester with Level IIIe
Channel Adapter