TELE3 SP Modem Configuration

The Configure tab allows you to enable the modem to provide secondary dial-up ISP
connection support and configure the modem settings. There are two sections available:
Modem Settings and Failover Settings.

Modem Settings

The Modem Settings section lets you select from a list of modem profiles, select the volume
of the modem, and also configure AT commands for modem initialization. To configure the
SonicWALL modem settings, follow these steps:
1. Select the Primary Profile from the list of profiles that the SonicWALL uses to access the
modem and dial the secondary connection. If you have enabled Manual Dial for the
Primary Profile, the Secondary Profile is not used.
2. Select the Secondary Profile from the list of profiles. If the Primary Profile cannot
establish a connection, the SonicWALL uses the Secondary Profile to access the modem
and establish a connection.
3. Select the volume of the modem from the Speaker Volume menu. The default value is
Medium.
4. Enter any AT commands used for the modem in the AT Commands (for modem
initialization) field. AT commands are instructions used to control a modem such as
ATS7=30 (allow up to 30 seconds to wait for dialtone), ATS8=2 (set the amount of time
the modem pauses when it encounters a "," in the string).
Note: The default settings for the modem are generally sufficient for normal operation. The
AT Commands (for modem initialization) box is provided for nonstandard situations.