Mounting the Inverter
Caution:
Risk of injury due to the heavy weight of the inverter (25 kg).
Take the weight of the inverter into consideration when lifting.
Select a suitable location for mounting.
It is preferrable to use two persons to mount the inverter.
►
To mount the Three Phase Inverter:
1 Attach the provided bracket to a wall or pole, as follows:
Ensure that the U-shaped part of the bracket is positioned on the
top, as shown below:
Figure 6: Positioning the U-shaped Part of the Bracket
When mounting on a wall, bolt the four outer-most holes of the
bracket.
Other holes may be used to stabilize the bracket or when the
outer-most holes cannot be used.
When mounting on a pole, bolt the suitable inner holes of the
bracket.
2 Verify that the bracket is firmly attached to the wall or pole.
SolarEdge Installation Guide for Three Phase Inverters – EU
Installing the Inverter
27