2 serial port debugging assistants, select the serial port baud rate to be 9600bps ( default ) , and the
verification method to be 8N1 , then the serial port transparent transmission can be realized;
If the customer needs to switch the working mode, it can be controlled by the Mode button to switch between
different working modes ( M0 indicator light, M1 indicator light). Press and hold the Mode button for 1ms and then
release it to switch the mode once. The details of the mode switch are shown in the following table :
Model
Name
Mode 0
General mode
Mode 1
Reserved mode
Mode 2
Command mode
Mode 3
Sleep mode
Note: The radio has the function of power-down save mode (the factory default setting is transparent
transmission mode), the user needs to switch the corresponding mode according to the M1 and M0 indicators
(effective immediately).

Description of each department

1.4.
Copyright ©2012–2022, Chengdu Ebyte Electronic Technology Co.,Ltd.
M1
M0
Serial port open, wireless open, transparent
ON
ON
transmission (factory default mode)
ON
OFF
Meaningless, both serial and wireless are closed
Radio can be programmed using configuration
OFF
ON
software
The module goes to sleep, the serial port and the
OFF
OFF
module are closed
E95-DTU(433C30-485) User Manual