6. Specifications

Key Jack:
Power Connector:
RF Output Connector:
Headphone/Speaker Jack:
Frequency Range:
Antenna Impedance:
DC Power Requirement:
Operating Temperature Range:
Dimensions (H×W×D):
(not including feet, knobs, connectors)
Weight:
Construction:
RF Power Output:
at 13 VDC; reduced output at
Harmonic & Spurious Outputs:
Meets FCC specifications

7. In Case of Difficulty

Typical procedures should be followed when
the unit does not operate or when one or more
functions do not work properly:
Check power supply voltage and polarity,
loose connections and correct connector.
Check that ALL band selection jumpers are in
either the "20M" or "40M" positions.
506 / Rebel Users Manual
Part #74482
Printed in USA
1/8" stereo
2.1 mm coaxial
BNC female
1/8" stereo
7.000-7.300 MHz
14.000-14.350 MHz
50 ohms
10-15 volts
0-50º C
2.0"×6.0"×4.0"
1.33 lbs.
Painted steel enclosure
Approximately 5 watts
lower supply voltages
Release 1.00 – August 2013
Verify that a proper antenna is connected for
the selected band.
Programming-related problems are best han-
dled with the assistance of members of Rebel
and Arduino user groups. Remember, you may
restore the unit to its original factory-provided
operation with the official TEN-TEC released
software.
TEN-TEC service may be contacted by e-mail
at: service@tentec.com, or by telephone at
(865) 428-0364.

8. Warranty and Return Policy

Warranty policy for Ten-Tec products is cov-
ered on the last page of this manual.
Return Policy for Equipment Manufactured by
TEN-TEC: TEN-TEC factory built radio
equipment is sold under a 30-day risk-free
trial period. Any piece of equipment manufac-
tured by TEN-TEC may be returned, undam-
aged, within 30 days of purchase for a full
purchase price refund, less shipping charges
(customer pays shipping both ways).
If you want to return a piece of equipment
purchased from TEN-TEC, please call the
sales department at (865) 453-7172 from 8
a.m. to 5 p.m. Eastern time, Mon-Fri and
obtain a return merchandise authorization
number. Calling in advance for an RMA num-
ber allows us to quickly process your return
and refund once your item arrives. Ship return
items with letter enclosed inside the box not-
ing the RMA number and your name, address,
and telephone number. Return items are
shipped to: TEN-TEC Inc., 1185 Dolly Parton
Pkwy, Sevierville, TN 37862 USA.
10