Certification
6.2 EMC and Environmental Type Tests
Oscillatory
HV Impulse
Environmental Type Tests
32
Description
DC Power Ports
AC Power Ports
Earth Ground Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Dielectric
Signal Ports
Strength
DC Power Ports
AC Power Ports
Test
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
2.5 kV Common and Differential Mode @ 1MHz
2.5 kV Common and Differential Mode @ 1MHz
Description
Cold Temperature
Dry Heat
Humidity (Damp
Heat, Cyclic)
Vibration
Shock
Test Levels
± 4 kV
± 4 kV
± 4 kV
2.5 kV Common mode @ 1MHz
5 kV (Failsafe Relay)
5 kV
5 kV
2 kVAC (Failsafe Relay)
1.5 kVDC
2 kVAC
Test Levels
Severity Levels
Test Ad
-40 °C (-40 °F), 16 Hours
Test Bd
85 °C (185 °F), 16 Hours
Test Db
95% (non-condensing),
55 °C (131 °F), 6 cycles
@ 10-150 Hz)
Level 2 (30 g @ 11 ms)
Installation Manual, 11/2022, C79000-G8976-1013-04
Level 2 (2 g
RUGGEDCOM RS1600