Installing Device
2.4.3 Wiring Examples
2.
3.
4.
2.4.3
Wiring Examples
The following illustrate how to connect power to single and dual power supplies.
Figure 2.6
Figure 2.7
14
Chassis Ground Terminal
4
Figure 2.5
Terminal Block Wiring
Connect the negative wire from the power source to the negative/neutral (-/N)
terminal on the terminal block.
Using a braided wire or other appropriate grounding wire, connect the surge
ground terminal to the chassis ground connection. The surge ground terminal
is used as the ground conductor for all surge and transient suppression circuitry
internal to the unit.
Connect the ground terminal on the power source to the chassis ground
terminal on the device.
+/H
-/N
POWERSUPPLY1
Single AC Power Supply
Single DC Power Supply
THIS DEVICECOMPLIES WITH PART15 OF
FAILSAFE
THEFCCRULES. OPERATION IS SUBJECTTO
THEFOLLOWING TWO CONDITIONS: (1) THIS
RS232 PORT
DEVICEMAYNOTCAUSEHARMFUL
INTERFERENCE, AND (2) THIS DEVICEMUST
ACCEPTANYINTERFERENCERECEIVED,
INCLUDING INTERFERENCETHATMAYCAUSE
UNDESIRED OPERATION.
+/H
-/N
POWERSUPPLY2
RUGGEDCOM RS1600
Installation Manual, 11/2022, C79000-G8976-1013-04