Download Print this page

permaban AlphaJoint Installation Manual

Advertisement

Quick Links

www.rcrflooringproducts.com
RCR Flooring Products Limited
Mill Close, Lee Mill Industrial Estate, Ivybridge, Devon, PL21 9GL
t: +44 1752 895288
f: +44 1752 395800
e: info@rcrflooringproducts.com
Permaban AlphaJoint Installation Guide
Using Pin & Weld Method
Installation Guide Issue V1.0
14/07/22
01 Placing the AlphaJoint
Place joints on the floor with sleeves pointing up.
02 Place pins
Pins are situated towards the end of the stud, then tack welded in place. The tack weld will break
under the pressure of the concrete, this will allow the joint to open along the length of the stud with
the pin still in place.
Note: 4 pins per joint.
Pin
Plastic sheet
Pin
Sleeve
Pin
Pin
Edge of Stud
Pin
All content found within this installation guide is approximate. RCR Flooring Products Ltd reserves the right to amend this
installation guide at any time. For further details, please contact RCR Flooring Products Ltd.
Note; Tack weld
to end of stud.
RCR Flooring Products Ltd is registered in England & Wales - No. 02815314.

Advertisement

loading

Summary of Contents for permaban AlphaJoint

  • Page 1 RCR Flooring Products Limited Mill Close, Lee Mill Industrial Estate, Ivybridge, Devon, PL21 9GL t: +44 1752 895288 f: +44 1752 395800 e: info@rcrflooringproducts.com Permaban AlphaJoint Installation Guide Using Pin & Weld Method Installation Guide Issue V1.0 14/07/22 01 Placing the AlphaJoint Place joints on the floor with sleeves pointing up.
  • Page 2 Permaban AlphaJoint Installation Guide Using Pin & Weld Method Installation Guide Issue V1.0 14/07/22 03 Fix joints together Position joints end to end, unscrew the wing nut and nylon, push the 60mm offsets together and re-assemble the nylon and wing nut. Note; The 4010 top strip may move laterally during transit and require minor realignment during installation.
  • Page 3 Permaban AlphaJoint Installation Guide Using Pin & Weld Method Installation Guide Issue V1.0 14/07/22 05 Adjust universal divider plate To extend the universal divider plate, pull out, push down and insert. Universal divider plate 140 Joint 160 Joint 160 Slab...
  • Page 4 Permaban AlphaJoint Installation Guide Using Pin & Weld Method Installation Guide Issue V1.0 14/07/22 Extended Joint support bar The re-bar is to be tack welded only. 07 Vibrate Concrete Poker vibrate along length of the joint to compacted concrete. Poker...