Page 1
RCR Flooring Products Limited Mill Close, Lee Mill Industrial Estate, Ivybridge, Devon, PL21 9GL t: +44 1752 895288 f: +44 1752 395800 e: info@rcrflooringproducts.com Permaban AlphaJoint Installation Guide Using Pin & Weld Method Installation Guide Issue V1.0 14/07/22 01 Placing the AlphaJoint Place joints on the floor with sleeves pointing up.
Page 2
Permaban AlphaJoint Installation Guide Using Pin & Weld Method Installation Guide Issue V1.0 14/07/22 03 Fix joints together Position joints end to end, unscrew the wing nut and nylon, push the 60mm offsets together and re-assemble the nylon and wing nut. Note; The 4010 top strip may move laterally during transit and require minor realignment during installation.
Page 3
Permaban AlphaJoint Installation Guide Using Pin & Weld Method Installation Guide Issue V1.0 14/07/22 05 Adjust universal divider plate To extend the universal divider plate, pull out, push down and insert. Universal divider plate 140 Joint 160 Joint 160 Slab...
Page 4
Permaban AlphaJoint Installation Guide Using Pin & Weld Method Installation Guide Issue V1.0 14/07/22 Extended Joint support bar The re-bar is to be tack welded only. 07 Vibrate Concrete Poker vibrate along length of the joint to compacted concrete. Poker...