ASC_RPA_de_en_nl_da_sv.book Seite 86 Dienstag, 5. Februar 2008 3:10 15
Service tasks
3. In standby mode, use the cursor keys
"Free selection":
4. Press ENTER to confirm.
5. ASC2000RPA only: to significantly reduce the duration of the
evacuation process, "nitrogen test" can be deselected in the
default settings (see "Editing default values" on page 63).
6. Select "Vacuum phase ?" (see "Free selection" on page 73) and carry
out a vacuum phase with a duration of one minute.
7. Using the refrigerant draining station, WAECO item number
8885200059, empty the vehicle's air conditioning system
according to the instructions in the operating manual.
8.7

Correcting the filling quantity for long service hoses

If longer or shorter service hoses are required for the device, you need to
adjust the filling quantities to the new hose lengths.
The service hoses for the high and low pressure sides must always be
of the same length, as otherwise the filling quantities will not be correctly
measured.
1. In standby mode, use the cursor keys
"Other selections":
2. Press ENTER to confirm.