Connecting Nitrogen Bottles (Asc2000Rpa Only) - Dometic AirCon ASC 1000 Operating Manual

Service center
Table of Contents

Advertisement

Available languages

Available languages

ASC_RPA_de_en_nl_da_sv.book Seite 68 Dienstag, 5. Februar 2008 3:10 15
First start-up
6.10 Connecting nitrogen bottles
(ASC2000RPA only)
To check for leaks using the nitrogen test, an external nitrogen bottle
needs to be connected to the AirCon Service Center.
The pressure at the nitrogen bottle's output must not exceed 12 bar.
1. Set the pressure regulator on the nitrogen bottle to max. 12 bar.
2. Hook up the connection hose to the nitrogen bottle and the
connection (8) for the nitrogen bottle.
3. Open the nitrogen bottle's valve.
68
8
AirConServiceCenter