4 INSTALLATION & PUMP CONNECTIONS
4.11 Mains water connection to iBoost 200 CAT 5: The iBoost is to be
permanently connected to the mains water supply using rigid pipe or
suitably sized and rated flexible hose to comply with current building and
plumbing regulations.
The water tank fill valve has a G ½ male threaded fitting; a suitable 90
type fitting must be used. When tightening ensure the fill valve within the
tank is not rotated. If the valve is rotated it may not function correctly with
the risk of flooding.
Ensure there is a demountable joint in the pipe to allow the removal of the
iBoost if needed (see Fig. 8).
4.12 Water outlet pipework:
1. The pump has a G ¾ threaded connection to accept the supplied hose.
The hose is made water tight with a sealing washer on assembly, nip
tight to 4 to 5 Nm for water tight seal. (Do not overtighten). The supplied
hose must only be connected to 22 mm pipework.
Ensure the pipe is free from all score marks and deformities in the area of
the insertion depth (Fig. 4) and cut the pipe square removing all burrs and
sharp edges to prevent damage to the sealing 'O'-ring.
2. Prior to inserting the pipe into the fitting mark the insertion depth on the
wall of the pipe with a soft pencil at a distance of 33 mm from the end to
be inserted.
3. Check in the mouth of the fitting that the 'O'-ring, nylon washer and collet
are in position.
Pencil mark
Fig. 5
- 9 –
Pipe
Fig. 4
Collet
Body
Washer
'O'-ring
Pipe stop
Hose
o
elbow