Superior WRE6842RS Installation And Operation Instruction Manual page 16

Indoor/outdoor wood burning fireplace
Table of Contents

Advertisement

OPTIONAL GAS LINE INSTALLATION
Gas line hook up should be done by your
supplier or a qualified service person.
Note: Before you proceed, make sure your
gas supply is turned off.
Use only a 1/2" black iron pipe and appropri-
ate fittings.
1. Remove knockout indentation on refrac-
tory or firebrick wall located above refrac-
tory hearth floor. Knockout indentation
must be firmly tapped with any solid object
such as a 1/2" dowel until it is released.
Remove fragmented portions of refractory
(see Figure 26).
2. Remove gas line cover plate located on
either side of fireplace and pull out insula-
tion from gas line conduit sleeve. Save
insulation for reuse. Replace screws.
3. Run a 1/2" black iron gas line into fireplace
through the rear at gas line conduit sleeve (if
using a raised platform, add height). Provide
sufficient gas line into fireplace chamber for
f i r e - p a r t s . c o m
fitting connection (see Figure 27).
Note: Secure incoming gas line to wood
framing to provide rigidity for threaded end.
4. Repack insulation around gas line and into
sleeve opening. Seal any gaps between
gas line and refractory knockout hole with
refractory cement or commercial furnace
cement, Install the gas appliance or cap-off
gas line if desired.
CAUTION: All gas piping
and connections must be tested
for leaks after the installation
is completed. After ensuring
that the gas valve is on, apply
soap and water solution to all
connections and joints. Bubbles
forming show a leak. Correct
all leaks at once. DO NOT USE
AN OPEN FLAME FOR LEAK
TESTING AND DO NOT OPER-
ATE ANY APPLIANCE IF A LEAK
IS DETECTED. LEAK TESTING
SHOULD BE DONE BY A QUALI-
FIED SERVICE PERSON.
16
Outside of
Fireplace
Gas Line
Conduit
A gas line or gas log lighter may be installed
for the purpose of installing a vented or vent-
free decorative gas appliance incorporating an
automatic shutoff device and complying with
the Standard for Decorative Gas Appliances for
Installation in Vented Fireplaces, ANSI Z21.60
or American Gas Association draft requirements
for Gas Fired Log Lighters for Wood Burning
Fireplaces, Draft NO. 4 dated August, 1993.
If you install a decorative gas appliance
(vented gas log), the decorative gas appliance
must comply with the Standard for Decorative
Gas Appliance for Installation in Solid Fuel
Burning Fireplaces, ANS Z21.60 or Z21.84
and shall also be installed in accordance with
the National Fuel Gas Code, ANSI 7223NFPA
54 latest edition.
www.SuperiorFireplaces.US.com
WARNING: Do not operate an
unvented gas log set in this fire-
place with the chimney removed.
Outside of
Fireplace
Gas Line
Remove
Conduit
Knockout
Insulation
Gas
Conduit
Cover
Figure 26 - Gas Line Access
Incoming
1/2" Black
Iron Pipe
Seal
Opening
Repack
with
Insulation
Refractory
Cement
Figure 27 - Gas Line Installation
Side
Firebrick
Finished
Side
1/2" Dowel
Brick with
Access
Hole
Side
Firebrick
Finished
Side
Provide Enough
Threaded
End for Fitting
Connection
127011-01A

Advertisement