Navitar Motorized Zoom Systems Instruction Manual for Windows
upon sensing a downward motion command and then approach the desired
preset. The Autorun operation is halted by clearing the Autorun checkboxes or by
clicking the STOP button, which will stop the motors and clear all Autorun check
boxes automatically.
19.3 Preset Save Button
The Way Point Save button is used to load the current motor step position count
value into the preset window. The user positions the motor at some desired
location, most likely using the Jog buttons and by pressing the Save button, the
position value is automatically loaded into the preset window.
20
Dwell Time Entry Window
The Dwell Time entry window is used to set the time the system pauses at each
of the selected presets during the Autorun operation. The value entered is in
seconds. If the value is 0 during the Autorun operation, as soon as one preset is
reached, the motor will immediately continue onto the next position. The dwell
time setting is common to all presets.
Revision B
Page 20 of 23