AHW-4A1-60-R
⚫ The cable connections must be in accordance with the diagram located on the
bottom of the hob.
⚫ The cable type must be connected to the corresponding power supply terminal box.
⚫ You should use a good quality screwdriver to carefully, fully tighten ALL of the
terminal screws.
⚫ If when the hob is first switched on, only two of the zones work, you should
recheck that the terminal screws are all fully tightened. This should be done before
contacting the Customer Care Department.
⚫ IMPORTANT: The appliance must NOT be connected to the mains supply by
means of a 13A plug and socket.
⚫ This appliance must be wired into a 30 A double pole switched fused spur outlet,
having 3 mm contact separation and placed in an easily accessible position
adjacent to the appliance. It should not be located above the appliance and no
more than 1.25m away from it.
⚫ The cable can be looped if necessary, but make sure that is not kinked or trapped
when the hob is in position. Care must be taken to avoid the cable being in contact
with hot parts of the appliance.
Replacing the mains supply cable
 If the mains supply cable is damaged, then it must be replaced by an appropriate
replacement.
 The mains supply cable should be replaced in accordance with the following
instructions:
➢ Switch the appliance off at the control switch.
➢ Open the terminal block on the underside of the hob.
➢ Unscrew the terminal screws fixing the cable.
➢ The "green-yellow" earth wire must be connected to the terminal marked
must be about 10 mm longer than the live and neutral wires.
50-60Hz
H05VV-F 3G2.5
60Hz
H05VV-F 4G2.5
H05GG-F 4G2.5
H07RN-F 4G2.5