SAFETY INSTRUCTIONS
Specifications
High voltages capable of causing severe injury or death by electrical
shock are present in this unit.
To reduce risk of electrical shock, disconnect power before working on or around the system. More than one disconnect
switch may be required to de-energize the equipment before servicing.
This product is supplied with a grounding conductor and grounding-type attachment plug. To reduce risk of electric shock,
be certain that it is connected only to a properly grounded grounding-type receptacle. Do not remove the third prong from
the plug. The third prong is to ground the pump to help prevent possible electric shock hazard. Do not use an extension
cord.
Check electrical outlets with a circuit analyzer to ensure power, neutral, and ground wires are properly connected. If not, a
qualified, licensed electrician should correct the problem.
Wire pump system for correct voltage.
Check local electrical and building codes before installation. The installation and ventilation must be in accordance with
their regulations as well as the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act
(OSHA).
The flexible jacketed cord assembly mounted to the pump must not be modified in any way, with the exception of shorten-
ing the cord to fit into a control panel. Any splice between the pump and the control panel must be made within a junction
box mounted outside of the basin and comply with the National Electrical Code. Employ a licensed electrician.
Do not use the power cord for lifting the pump.
This pump has not been investigated for use in swimming pool or marine areas.
Risk of bodily injury, electric shock, or equipment damage.
This equipment must not be used by children or persons with reduced physical, sensory or mental abilities, or lacking in
experience and expertise, unless supervised or instructed. Children may not use the equipment, nor may they play with the
unit or in the immediate vicinity.
Equipment can start automatically. Always unplug the pump power cord and disconnect the electrical power before servic-
ing the pump or switch.
An inoperative or malfunctioning pump could lead to flooding, resulting in personal injury or property damage. In applica-
tions where property damage and/or personal injury might result from an inoperative or leaking pump due to power out-
ages, discharge line blockage, or any other reason, an automatic back-up system and/or an alarm should be installed.
Use with approved liquid level control with correct rating that matches marked motor input in full load amperes or service
factor amperes.
Do not run the pump dry. If run dry, the surface temperature of the pump will rise to a high temperature that could cause
skin burns if touched and will cause serious damage to your pump.
Do not oil the motor. The pump's motor housing is sealed, with a high-grade dielectric oil for heat transfer and lifetime
lubrication. Use of other oils could cause serious electric shock and/or permanent damage to the pump.
Operation of this equipment requires detailed installation and operation instructions provided in this manual. Read entire
manual before starting installation and operation. End User should receive and retain manual for future use.
The pump has been evaluated for use with water only. Pump should only be used with liquids compatible with pump com-
ponent materials. If the pump is used with liquids incompatible with the pump components, the liquid can cause failure to
the electrical insulation system resulting in electrical shock.
Keep safety labels clean and in good condition.
Refer to product data plate(s) for additional precautions, operating instructions, and specifications.
Risk of damage to pump or other equipment.
Do not use this pump for pumping sea water, beverages, acids, chemical solutions, or any other liquid that promotes corro-
sion as this can result in damage to the pump.
Do not run pump dry. For optimal cooling and to prolong the motor life, the liquid level being pumped should normally be
above the top of the pump housing.
This pump is not suitable for pond applications.