Menu
TEST PRINT XX
Printing Test
Used to perform self-printing under the set conditions, and to adjust and check the engine set value.
*Pressing [
XX(select the number changed to decimal.)
Aging mode:
Set value
XX
10
11
12
13
14
15
example: If you need "Aging mode" only, select "16".
*Pressing [OK] key displays the setting menu for printing test.
*Pressing [MENU] moves to the next item
*Using [
*Pressing [BACK/C] key releases the printing menu mode.
*Pressing [OK] key starts the printing test.
*DATA ( LED) blinks during the TEST PRINT execution.
TEST PRINT 00
] or [
] key selects the mode.
7
6
5
4
3
Mode
0
1
No jam detection
2
No fusing control
3
No fusing control + No jam detection
4
No warm-up cycle
5
No warm-up cycle + No jam detection
6
No warm-up cycle + No fusing control
7
No warm-up cycle + No fusing control
+ No jam detection
8
No DV detection
9
No DV detection + No jam detection
No DV detection + No fusing control
No DV detection + No fusing control
+ No jam detection
No DV detection + No warm-up cycle
No DV detection + No warm-up cycle
+ No jam detection
No DV detection + No warm-up cycle
+ No fusing control
No DV detection + No warm-up cycle
+ No fusing control + No jam detection
If you need "Aging mode" and "No jam detection", select "17".
] and [
] keys changes the mode.
Content
2
1
0
1 : No Jam detection
1 : No Fuser Control
1 : No warm up cycle
1 : No Developer detection
1 : Aging mode
Set value
XX
16
Aging mode
17
Aging mode + No jam detection
18
Aging mode + No fusing control
19
Aging mode + No fusing control
+ No jam detection
20
Aging mode + No warm-up cycle
21
Aging mode
+ No warm-up cycle No jam
detection
22
Aging mode + No warm-up cycle
+ No fusing detection
23
Aging mode + No warm-up cycle
+ No fusing detection
+ No jam detection
24
Aging mode + No DV detection
25
Aging mode + No DV detection
+ No jam detection
26
Aging mode + No DV detection
+ No fusing control
27
Aging mode + No DV detection
+ No fusing control
+ No jam detection
28
Aging mode + No DV detection
+ No warm-up cycle
29
Aging mode + No DV detection
+ No warm-up cycle
+ No jam detection
30
Aging mode + No DV detection
+ No warm-up cycle
+ No fusing control
31
Aging mode + No DV detection
+ No warm-up cycle
+ No fusing control
+ No jam detection
AR-P350 DIAG 10-14
Initial
value
Mode
Set
range