Powerfail alarm :
ALARM :
POWERFAIL
START :
Start date and time of alarm situation
END :
End date and time of alarm situation
AVG :
Average temperature on the display sensor during the alarm situations
• To delete the alarm history, select the function "DELETE HISTORY" from the EXTRA menu.

Rechargeable battery

• The monitoring functions of the electronics
during an interruption of the power supply for at
least 48 hours are maintained by an integrated
rechargeable battery.
• This battery is automatically charged when the
appliance is connected.
• If the capacity of the battery is no longer
sufficient to take over the control function, the
error message "BAT.1 LOW/FAIL" appears on the
display.

External Alarmfunction

• There are two terminals with three floating
contacts on the back of the unit that can be used
to trigger an additional external alarm (visual or
audible).
• The upper contacts correspond to temperature-
and door-alarm, the lower contacts correspond to
a powerfail-alarm.
• Pressing the ENTER-key in an alarm situation
only switches off the internal audible alarm. The
key does not interfere with the external alarm.
The external alarm signal is only switched off
once the cause of the alarm has been eliminated.
• A voltage of between 12V DC and a maximum of
250V AC can be connected at the contacts. The
maximum load must not exceed 8A. The minimum
power rating is 100mA / 5V.

Safety thermostat

• All units are fitted with a safety thermostat. This
thermostat switches off the compressor as soon
as the inside temperature falls below +2°C, to
prevent the goods being harmed by freezing.

Interior fittings

• Depending on the model series, height-
adjustable drawers or racks are included as
standard fittings.
• The load must be evenly distributed over the
drawers or racks.
• At the first starting up it may happen that the
message „BAT.1 LOW/FAIL" appears. The message
will disappear as soon as the battery is charged.
• The battery should be pre-emptively replaced
every 2 years. This replacement must only be
carried out by a recognised service technician.
Before dismantling the battery the appliance
must be switched off and the plug pulled out.
• The battery is a lead-acid storage battery that
must be disposed of separately in the case of a
fault.
TEMPERATURE-ALARM
DOOR-ALARM
Resting state
Alarm
• Pull out the drawers using the handles only.
• To remove the drawers (e.g. to clean them), pull
the draw out to the stop and then lift.
• The appliances are designed in such a way that
they have optimal function with the original
fittings. If interior fittings from other suppliers
are to be used, this must be definitely agreed
with the manufacturer.
13
POWERFAIL-ALARM