GBM-1

7. Technical data

Number of
monitored sections
Evaluation of the
occupancy messages
Inputs and outputs
Inputs
Outputs
Electrical characteristics
Power supply
Current consumption
(without connected loads)
Maximum current
in the monitored sections
Max. current per output
Max. total current of the
outputs
Sensivity
Protection
Protection class
24 | Technical data
maximum 4
against earth of the downstream components
4 inputs for the connection of the monitored track sections
4 outputs for the connection of
external indicator LEDs or lamps
subordinate circuits
the inputs of digital feedback devices
12 – 18 Volt a.c. or d.c. voltage
The GBM-1 must not be supplied by transformers or a
!
digital boosters providing current for driving operation.
approx. 15 mA
1 200 mA
500 mA
2 000 mA
1 mA
Ready-made module (without housing): IP 00
Meaning: No protection against foreign bodies, contact and water.
Ready device (in housing): IP 20
Meaning: Protected against solid foreign bodies with diameter ≥ 12.5 mm and
access with a finger. No protection against water.