1.5. Care........................5 2. Operation overview.......................6 2.1. Use in analogue layouts..................6 2.2. Use in digital systems...................7 3. Connections GBM-8.2....................8 3.1. Connecting the power supply and the track sections..........8 3.3. Connection of LEDs....................10 3.4. Connection of digital feedback modules...............11 4. Setting the sensitivity....................12 5.
If you pass the track occupancy indicator on to another person, also give the instructions with it. 1.1. Contents of the package 1 ready-built and tested circuit board GBM-8.2 (item no. 52-01186-01) or 1 track occupancy indicator GBM-8.2 in housing (item no. 52-01187-01) 1.2. Accessories Connection cables The use of stranded wire is recommended for making the connections.
GBM-8.2 1.4. Safety instructions Note: The track occupancy indicator contains integrated circuits (ICs). These are sensitive to electrostatic charging. Therefore, do not touch these components until you have "discharged" yourself. For this purpose, e.g. a grip on a radiator is sufficient.
To display the busy messages, LEDs (with suitable series resistors) can be connected to the outputs of the GBM-8.2. Since the outputs of the GBM-8 can be loaded with a maximum of 50 mA each, they are not suitable for connecting incandescent lamps, relays or downstream circuits with a higher current consumption.
GBM-8.2 2.2. Use in digital systems The GBM-8.2 can be used independently of the digital format with which the layout is controlled. A typical application in digital systems is the combination with feedback modules that read in ground contacts (e.g. s88 feedback modules). The eight outputs of the GBM-8.2 are arranged in such a way that they can be directly connected to the inputs of the s88 feedback modules from the Tams Elektronik product range (e.g.
Please note: If you use a DC voltage transformer as the + / ~ driving transformer, you must always observe the polarity when - / connecting it. If you use an AC voltage transformer, the polarity is not important. 8 | Connections GBM-8.2...
Page 9
Track sections that are to be switched off during operation (e.g. in a staging yard) can also be monitored with the GBM-8.2. For this purpose, a resistor with a value < 1.5 kW must be installed in the supply line to the track section concerned in such a way that it bridges the switch in the switched-off state.
No incandescent lamps! Never connect incandescent lamps to the outputs, as they usually consume more than 50 mA of current. The outputs of the GBM-8.2, which are designed for a maximum current of 50 mA, would be destroyed during commissioning!
You can connect the inputs of digital feedback modules that switch to ground (e.g. s88 feedback modules) directly to the outputs of the GBM-8.2. Connect the ground output of the feedback module to one of the two connections M of the GBM-8.2.
GBM-8.2 tams elektronik 4. Setting the sensitivity Adjust the sensitivity of the track occupancy detector for each of the 8 track sections at the associated trim pot. Use a small screwdriver for the adjustment. Settings: Left stop: highest sensitivity (setting on delivery) ...
Possible causes: One or more connections are faulty. à Check the connections. The GBM-8.2 is defective. à Send the track occupancy indcator in for inspection. Connected LEDs do not light up Possible causes: The power supply is interrupted. à Check the connection of the LEDs and the track occupancy detector to the transformer supplying the LEDs.
GBM-8.2 tams elektronik 6. Technical data Number of monitored sections maximum 8 Evaluation of the occupancy messages against mass of the downstream components Galvanic isolation between inputs and outputs Inputs and outputs Inputs 8 inputs for the connection of the monitored track sections...
Page 15
GBM-8.2 Environment For use in closed rooms Ambient temperature during operation 0 ~ + 30 °C Permissible relative humidity during operation 10 ~ 85% (non-condensing) Ambient temperature during storage - 10 ~ + 40 °C Permissible relative humidity...
GBM-8.2 tams elektronik 7. Warranty, EU conformity & WEEE 7.1. Guarantee bond For this product we issue voluntarily a guarantee of 2 years from the date of purchase by the first customer, but in maximum 3 years after the end of series production. The first customer is the consumer first purchasing the product from us, a dealer or another natural or juristic person reselling or mounting the product on the basis of self-employment.
GBM-8.2 7.2. EU Declaration of Conformity This product fulfils the requirements of the following EU directives and therefore bears the CE marking. 2001/95/EU Product Safety Directive 2015/863/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) 2014/30/EU on electromagnetic compatibility (EMC Directive).