WArning! The air tank is a pressure vessel and the following safety measures apply:
dO NOT tamper with the safety valve, dO NOT modify or alter the tank in any way and dO NOT strap anything to the tank.
dO NOT subject the tank to impact, vibration or to heat and dO NOT allow contact with abrasives or corrosives.
dO drain condensation from tank daily, inspect inside walls for corrosion every three months and have a detailed tank inspection
carried out annually.
The tank shell must not fall below the certified thickness at any point.
WArning! if an electrical fuse blows, ensure it is replaced with an identical fuse type and rating (see para. 1.1.10).
2. introDuction & speciFicAtions
features cast iron cylinder head configuration from Premier Line range of compressors. compact size and quiet running features make this
compressor unit suitable for installation near or in workshop area. noise output is just 63dB.A - not much more than a washing machine!
includes heavy-duty single-phase electric motor with soft start circuitry to enable smooth operation from 13Amp supply. integral 24 litre tank
may be supplemented by additional receiver (see sA200t). Provides both regulated and unregulated pressure output with glycerine filled
gauges on control panel for precise adjustment. supplied with full cE certification, test certificate and full operation/maintenance booklet. unit
may not be converted for mobile use.
2.1.
specifications
max.
motor
model
output
(hp/kW)
sA4025/3.v3
3/2.2
2.2.
Weights & Dimensions
Weight
model
(kg)
sA4025/3.v3
110
3. instALLAtion
3.1.
the compressor is supplied factory assembled, but should be checked to ensure that it is in good order and condition before installing.
3.2.
the compressor must be positioned so that the panels may be removed and compressor components easily accessed for
maintenance. the location must have good air exchange and an adequate air flow around the unit as the compressor generates
significant heat. in contaminated areas an extraction system must be installed to remove dust, vapours and gases. Do not install the
compressor in very high dust locations.
to achieve minimum clearance around the compressor unit see fig.1 below, which also shows a multi-installation arrangement.
3.3.
confirm the mains voltage corresponds with the voltage shown on compressor data plate.
3.4.
Ensure there is adequate lighting and sufficient room to locate other equipment to be used with the compressor without obstructing air
flow.
3.5.
the compressor must be stood on the floor. the floor must be flat and level. check that the floor is strong enough to support the
compressor. Do not stand on an additional support, such as a pallet.
3.6.
the compressor may be moved by passing fork lift blades through the lifting location in the base of the unit.
3.7.
system set-up
the following illustration demonstrates the type and order of component set-up that may be used with the unit.
voltage/
current
pump
phase
(A)
type
230/1
13
K17
Dimensions
Depth x Width x Height (mm)
620 x 700 x 1100
pump
piston
speed
Displacement
(rpm)
(cfm)
1000
14.9
All performance figures are ± 5%
* note: 2.5 bar is recommended pressure setting for spraying.
fig. 1
fig. 2
1. compressor
2. to additional compressors (optional)
3. Electrical socket
4. Air cooler (optional)
5. External tank (optional)
6. Air drier (optional)
7. Air outlet
Original Language Version
Free Air Delivery
(cfm)
capacity
At
At
max.
2.5 Bar*
6.0 Bar*
12.0
11.1
9.9
6.0 bar is recommended pressure setting for air tools.
sA4025/3.V3
tank
max.
noise
pressure
Level
(ltr)
(psi/bar)
(dB.A)
24
145/10
63
issue: 2 - 21/10/09