Ezon Professional Hiking Series Operation & Instruction Manual

Ezon Professional Hiking Series Operation & Instruction Manual

Hide thumbs Also See for Professional Hiking Series:
Table of Contents

Advertisement

登 山 运 动 腕 表 系 列
Professional Hiking Series
使 用 说 明 书
Operation Instruction Manual
EN

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Professional Hiking Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ezon Professional Hiking Series

  • Page 1 登 山 运 动 腕 表 系 列 Professional Hiking Series 使 用 说 明 书 Operation Instruction Manual 中...
  • Page 2 M601-1...
  • Page 3: Table Of Contents

    目 录 1.简介............1 2.功能特征..........1 3.表盘、按键和指针.......1 4.时间和温度计........2 4.1.时间模式 ........2 4.2.时间设置.........2 5.指 南 针..........3 5.1.指南针模式........3 5.2.指南针校正........3 6.高 度 计..........4 6.1.高度计模式 ........4 6.2.高度读数.........5 6.3.高度校正.........5 7.指针校正..........6 8.更换电池..........7 9.防水性 ..........8 10.注意事项..........9 11.产品规格..........9...
  • Page 4: 功能特征

    1.简介 感 谢 您 购 买EZON宜 准 运 动 腕 表 , 在 使 用 之前请仔细阅读说明书。了解该产品的功能、 操作方法及注意事项。 本表为指针式运动表,除计时功能外,带 有指南针、高度计和温度计等功能。 2.功能特征 指针时间 高 度 计 指 南 针 温 度 计 50米防水 3.表盘,按键和指针 12点位 时钟刻度盘 指南针刻度盘 零刻度 温度刻度盘 高度千位刻度盘 高度尾数刻度盘 本表有3个功能模式:时间模式、指南针...
  • Page 5: 时间和温度计

    位或零刻度,说明指针需要校正,校正方法参 见第7章。 4.时间和温度计 4.1.时间模式 本 表 常 规 为 时 间 模 式 。当秒针顺时针跳 转,说明手表处于时间模式, 此 时 各 指 针 功 能 如 下图。 时针 分针 秒针 温度指针 在时间模式,可查看时间和温度。 4.2.时间设置 1)进入时间设置状态: 在时间模式,按住[B]键直到秒针停止转 动; 2)秒针校零: 按[A]键或[C]键顺时针或逆时针调整,或按 住[A]键或[C]键快速调整,直到秒针正对12点 位(如果秒针已指向12点位,可以跳过此步骤); 3)设置分针和时针: 先按一下[B]键,再按[A]键或[C]键顺时针 或逆时针调整,按住[A]键或[C]键快速调整, 直到分针和时针指向当前时间;...
  • Page 6: 指南针

    设置时、分针 时间模式(走秒) 秒针校零 在时间设置状态,若无按键操作, 分钟后 手表自动返回到时间模式。 5.指南针 5.1.指南针模式 在时间模式或高度计模式 按[A]键 , 秒针转 向12点位再指向磁北,表示手表进入指南针模 式,此时各指针功能如下图。 时针 分针 指北针 温度指针 在指南针模式,可查看方位、时间和温度。 在指南针模式按[ B ]键 ,手表返 回 时 间 模 式(秒针先转向12点位,然后指向当前时间, 开始走时)。 5.2.指南针校正 为了确保测量方位的准确性,出现下列情 况要进行指南针校正:...
  • Page 7: 高度计

    1)更换电池后; 2)到新的地区; 3)指南针被磁化; 4)指南针测量不准确。 指南针校正方法:在指南针模式,按住[A] 键直到指北针停止在12点位,表示进入指南针 校正状态;保持手表水平慢速旋转至少2圈(每圈 约15秒),直到指北针重新指向磁北位置,表示 校正完成,手表自动返回指南针模式。 指南针模式 校正指南针 指南针校正过程中,按[B]键可取消校正, 手表返回指南针模式。 在指南针校正状态,若无按键操作,30秒 后手表自动返回指南针模式。 在指南针模式,若无按键操作,30秒后手 表自动回到时间模式。 建议在户外远离磁场的空旷场所校正。 6.高度计 6.1.高度计模式 在时间模式或指南针模式,按[C]键秒针和 温度指针分别转向12点位和零刻度,然后指向 高度,表示手表进入高度计模式,此时各指针功 能如下图。...
  • Page 8: 高度读数

    时针 分针 高度尾数指针 高度千位指针 在高度计模式,可查看高度和时间。 在高度计模式按[B]键,手表返回时间模式 (秒针先转向12点位,然后指向当前时间,开始 走时)。 6.2.高度读数 在高度计模式,高度尾数指针指示1000米 内的 读 数 , 高 度 千 位 指 针 指 示 千 位 读 数(读 数X1000米)。 如右图:在高度 计模式,高度尾数指 针指向刻度400,高 千位数指针指向刻度 5,表示当前高度 是:5X1000+400= 高度计模式 5400米。 6.3.高度校正 使用本表测量海拔高度前,需先设置当前 高度以校正高度计,方法如下: 1)进入高度校正状态: 在高度计模式,按住[C]键直到高度尾数指 针和高度千位指针分别指向12点位和零刻度;...
  • Page 9: 指针校正

    2)设置当前高度: 按[A]键或[C]键增减高度,按住[A]键或[C] 键快速增减高度(高度尾数指针每转动一圈,高 度千位指针会自动跳转一格,表示高度增或减 1000米); 3)退出高度校正状态: 按[B]键,手表返回高度计模式。 高度计模式 高度校正 在高度校正状态,若无按键操作,30秒后 手表自动返回高度计模式; 在高度计模式,若无按键操作,3分钟后手 表自动返回时间模式。 7.指针校正 1)进入指针校正状态: 在时间模式同时按住[A][B][C]3个按键, 直到秒针、时针和分针、温度指针均停止不 动; 2)调整秒针: 按[A]键或[C]键顺时针或逆时针调整秒针, 按住[A]键或按[C]键快速调整,直到秒针指向 12点位; 3)调整分针和时针: 先按一下[B]键,再按[A]键或[C]键可顺时 针或逆时针调整分针和时针,按住[A]键或[C] 键快速调整,直到分针和时针一起指向12点 位;...
  • Page 10: 更换电池

    4)调整温度指针: 先按一下[B]键,再按[A]键或[C]键顺时针 或逆时针调整温度指针,按住[A]键或[C]键快 速调整,直到温度指针指向零刻度。 5)退出指针校正状态: 按住[B]键,手表返回时间模式。 时间模式 校正秒针 校正分针和时针 校正温度指针 更换电池后,手表自动进入指针校正状态。 指针校正后需重新设置时间。 8.更换电池...
  • Page 11: 防水性

    指针校正状态 警告 - 请勿挤压或刺穿废旧电池,更不能 将其投入火中或水中,以免引起或灾。请正确 回收或丢弃废旧电池。 9.防水性 本表具有50米防水性,可佩戴洗手、凉水 淋浴、游泳,但不可佩戴潜水和桑拿等。 为保持防水性: 1)要 定 期 更 换 防 水 圈 , 一 般 是1-2年 , 如 不 更 换可能会因胶圈老化而受潮; 2)不能在水中操作按键。...
  • Page 12: 注意事项

    10.注意事项 警告 - 本表内置的高度,指南针,温度测 量功能不能用于精度要求高的专业场合。 注意 - 本表虽然符合行业标准,但本产品 与皮肤接触可能产生过敏反应或皮肤刺激。若 发生这种情况,请立即停止使用并咨询医生。 注意 - 本表由精密零件组装而成,请不要 自行拆卸或粗暴使用。 注意 - 不要在严寒,酷热,温度骤变的环 境中佩戴。 注意 - 不要在强磁,强电环境中佩戴。 注意 - 请确保传感器外表干净。 注意 - 请使用软布及清水清洁本表,不要 使用洗涤剂、溶剂、杀虫剂等化学品。 注意 - 本表如果出现功能异常,或者内部 出 现 水 珠 , 水 雾 等 , 请 找 有 资 质 的 维 修 点 维 修。...
  • Page 13 CONTENTS 1.Introduction.........1 2.Function..........1 3.Dial,Button and Hands......1 4.Time and Thermometer......2 4.1.Time Mode........2 4.2.Setting Time........2 5.Compass..........3 5.1.Compass Mode.......3 5.2.Calibrating Compass.......3 6.Altimeter..........4 6.1.Altimeter Mode........4 6.2.Getting Altitude Readings....5 6.3.Calibrating Altitude ......5 7.Calibrating Hands........6 8.Replacing Battery.........7 9.Water Resistant........8 10.Safety Information......9 11.Specification........9...
  • Page 14: Introduction

    1.Introduction Thank you for purchasing EZON sport watch. Please read this operation instruction to know the fun- ctions, the way of operation and the safety information before using the watch. This is a multi-functional watch which combines time, compass, altimeter and thermometer together.
  • Page 15: Time And Thermometer

    4.Time and Thermometer 4.1.Time Mode The watch is in the time mode usually. While the second hand is running clockwise, it means the watch is in the time mode, and the functions of watch hands are as the following picture. Hour Hand Minute Hand Second Hand...
  • Page 16: Compass

    Calibrating Second Hand Setting Minute & Hour Time Mode In the setting time status, the watch will return the time mode automatically if no button is operated within 1 minute. 5.Compass 5.1.Compass Mode Press button [A] i n the time mode or altimeter mode, the second hand rotate to 12 o`clock position, then point to the magnetic north.It means the watch is in the compass mode, and the functions of watch hands...
  • Page 17: Altimeter

    1)After replacing battery; 2)In a new area; 3)The compass has been magnetized; 4)The measurement error is too large. The way of calibrating compass is as following: In the compass mode, press down button [A] until the north hand points to 12 o`clock position. It means the watch is in the compass setting status.
  • Page 18: Getting Altitude Readings

    Hour Hand Minute Hand Altitude Mantissa Hand Altitude Multiple Hand While the watch is in the altimeter mode, you can view altitude and time. In the altimeter mode, press button [B] to return the watch to the time mode(the second hand rotates to 12 o`clock position, then points to the current time and begins running).
  • Page 19: Calibrating Hands

    2)Setting current altitude: Press button [A] or [C] to rotate the altitude man- tissa hand clockwise or anticlockwise, or press down button [A] or [C] to rotate the hand quickly (when altitude mantissa hand rotates a circle, the altitude multiple hand will rotate a cell in the same direction which indicates altitude plus or minus 1000 meters), to make the hands point to the current altitude;...
  • Page 20: Replacing Battery

    rotate minute hand and hour hand clockwise or anti- clockwise, press down button [A] or [C] to rotate qui- ckly, to make the minute hand and hour hand point to 12 o'clock position; 4)Calibrating the temperature hand: Press button [B], then press button [A] or [C] to rotate temperature hand clockwise or anticlockwise, or press down button [A] or [C] to rotate quickly, to make the temperature hand point to zero graduation.
  • Page 21: Water Resistant

    Watch Hand Calibration status Warning: In order to avoid the fire, please do not crush, puncture or even throw the used battery in fire or water. And please recycle or deal with it in reason- able way. 9.Water Resistant This watch is water resistant to 5 ATM .
  • Page 22: Safety Information

    10. Safety Information Warning: The altimeter, compass, thermometer in the watch cannot be used in professional field where require high accuracy. Note: This watch complies with industrial stand- ards, if there is any allergic reaction or skin irritation, please stop wearing it and consult a doctor. Note: This watch consists of precision electronic parts, please do not dismantle by yourself or use roughly.

This manual is also suitable for:

H601H603H607

Table of Contents