Wired controller

Advertisement

Operation
VIP ( Only valid for part of models)
(1) Setting method: Keep pressing the MENU key + 
key for
5 seconds to enter the advanced settings, the unit number is
displayed in the lower right corner, and the decimal display
area of the temperature flashes to display the function 
classification. Switch to H by clicking the FAN key. The function 
code is displayed in the integer area of the temperature zone.
At this time, press
or
keys to switch function code to 05.
Then press the MENU key to confirm, 05 in the temperature 
integer area is displayed statically, and the specific information 
in the clock display area is flashing. Pressing 
or
keys to
switch the parameters, and pressing the MENU key to confirm.
(2) In the clock display area, 1 means the local VIP is turned 
on, and 0 means the local VIP is turned off;
(3) If VIP is not set in the external machine system, any line 
controller of internal machine can be set with VIP function; if 
the external machine system has set VIP function, only the
VIP machine can be set up VIP on or off.
(4) After setting VIP function, if the internal machine is stated 
VIP function, the main interface will display the characters
"VIP"; if it is a non-VIP internal machine, and when the mode 
of internal machine is different from the VIP internal machine, 
the controller will display the "Mode conflict" icon.