Operation
Mode setting (only valid for part of models) 
(1) When controller is turned off, and the backlight is lit 
up, long press MODE key for 5 seconds to enter mode
setting interface. The parameter is displayed in the top-left
corner, and you can use
or
key to switch it between
00/01/02/03/04/06/07. After adjustment, you need to press 
MENU key to confirm changes.
(2) The correspondence between parameters and mode 
combinations is as follows:
00------------ [Auto] [Cooling] [Dry] [Fan] [Heating]
01------------ [Heating] [Cooling] [Dry] [Fan]
02------------ [Fan]  [Cooling]  [Dry]
03------------ [Heating] [Cooling] [Dry]
04------------ [Fan] [Heating] [Cooling]
06------------ [Heating] [Fan]
07------------ [Heating]
(04/06/07 is valid under the third edition communication 
protocol)
(3) Fresh Air unit can execute mode setting, it will execute 
the intersection with three modes of Fresh Air unit (cooling/
heating/fan mode).
Note:
This function requires indoor units support. If the indoor unit
does not support it, you may not be able to set it.