Download Print this page
Elster ACM M-BUS WIRE Operating Instructions

Elster ACM M-BUS WIRE Operating Instructions

Communications module for gas meters with absolute encoder ae2 with and without smart valve

Advertisement

Quick Links

Edition 02.10
www.docuthek.com
D
GB NL SK
 
Operating instructions
Communications module
ACM M-BUS WIRE,
ACM SCR+ WIRE for gas meters
with Absolute ENCODER AE2 with
and without smart valve
Translation from the German
© 2008-2010 Elster GmbH
Contents
Communications module
ACM M-BUS WIRE,
ACM SCR+ WIRE for gas meters with
Absolute ENCODER AE2 with and without
smart valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Checking the usage . . . . . . . . . . . . . . . . . . . . . 2
Type code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Part designations . . . . . . . . . . . . . . . . . . . . . . . . 2
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Installing the gas meter . . . . . . . . . . . . . . . . . . . 3
Attaching the ACM..WIRE . . . . . . . . . . . . . . . . . 3
Commissioning. . . . . . . . . . . . . . . . . . . . . . . . . 
Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . 3
Charging time . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . 
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Assistance in the event of malfunction . . . . . 
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 4
Declaration of conformity . . . . . . . . . . . . . . . . 4
Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Safety
Please read and keep in a safe place
Please read through these instructions
carefully before installing or operating. Following the
installation, pass the instructions on to the opera-
tor. This unit must be installed and commissioned
in accordance with the regulations and standards
in force. These instructions can also be found at
www.docuthek.com.
Explanation of symbols
• , 1 , 2 ,  ... = Action
= Instruction
Liability
We will not be held liable for damage resulting from
non-observance of the instructions and non-com-
pliant use.
Safety instructions
Information that is relevant for safety is indicated in
the instructions as follows:
DANGER
Indicates potentially fatal situations.
WARNING
Indicates possible danger to life and limb.
CAUTION
Indicates possible material damage.
All interventions may only be carried out by qualified
gas technicians. Electrical interventions may only be
carried out by qualified electricians.
Conversion, spare parts
All technical changes are prohibited. Only use OEM
spare parts.
Transport
On receipt of the product, check that the delivery is
complete (see Part designations). Report any trans-
port damage immediately.
Storage
Store the product in a dry place. Ambient tempera-
ture: see Technical data.
Disposal
Components are to be disposed of separately.
On request, old units may be returned carriage paid
to Elster GmbH in accordance with the relevant waste
legislation requirements (for Germany: KrW-/AbfG
[Act for Promoting Closed Substance Cycle Waste
Management and Ensuring Environmentally Compat-
ible Waste Disposal]).
GB-1

Advertisement

loading

Summary of Contents for Elster ACM M-BUS WIRE

  • Page 1 Declaration of conformity ....4 to Elster GmbH in accordance with the relevant waste Contact ....... 4...
  • Page 2 Electric shocks can be fatal! Before working on and forwarding absolute meter readings. possible live components ensure the unit is discon- ACM M-BUS WIRE additionally offers the “V-Drive” nected from the power supply. option. This means that activation and status mes- saging of the valve incorporated in the gas meter can ▷...
  • Page 3 BK-G1.6 to BK-G25T, see www.docuthek. 1 For removing the ACM..WIRE, the seal must be com → Elster-Instromet → Products → Gas pierced and broken with a screwdriver. measuring devices → Diaphragm meters → Diaphragm meters BK-G1.6 to BK-G25T op- erating instructions.
  • Page 4 M-BUS transfer of status and error messages in with communications module ACM M-BUS WIRE, accordance with EN 13757. ACM M-BUS WIRE V-Drive and ACM SCR+ WIRE Connection cable design: 2 m (other dimensions for gas meters BK-G comply with the requirements...