Advertisement

BYPASS DIAMETERS
BURNER
Auxiliary
Semi-rapid
Rapid
Triple Crown
Oven
Grill
GAS BURNERS FOR NATURAL GAS G20 20 mbar
BURNER
Triple Crown
Rapid
Semi-rapid
Auxiliary
Oven
Grill
GAS BURNERS FOR LPG G30 28-30 mbar
NORMAL POW-
BURNER
Triple Crown
Rapid
Semi-rapid
Auxiliary
Oven
Grill
GAS CONNECTION
WARNING! Before you connect the
gas, disconnect the appliance from the
electricity supply or switch off the fuse
in the fuse box. Close the primary
valve of the gas supply.
20
NORMAL POWER kW
3.8
2.9
1.85
0.95
3.9
3.0
GAS RATE g/h
ER kW
4.0
3.0
1.9
0.95
3.9
3.0
Ø BYPASS 1/100 mm
REDUCED POWER kW
1.8
1.1
0.45
0.35
1.5
-
REDUCED POWER
290.9
218.1
138.2
69.1
283.6
218.1
The gas pipe in the appliance has two endings. You
can connect the gas supply to either one of them.
The pipe that is not used must be clogged with the
pipe closer, which added to the appliance.
Use a fixed connections or use a flexible stainless
steel pipes in compliance with the regulation in
force. If you use flexible metallic pipes, make sure
29
32
55
67
54
-
INJECTOR MARK 1/100
INJECTOR MARK
kW
1/100 mm
1.8
1.1
0.43
0.35
1.5
-
mm
146
119
96
70
136
126p
101o
88
71
50
95
88

Advertisement